OPERATING INSTRUCTIONS
AM-86X65 ANALOGUE PANEL METER
ITEM NO.: 10 30 73
5 A/DC
ITEM NO.: 10 30 74
15 A/DC
ITEM NO.: 10 30 75
15 V/DC
ITEM NO.: 10 30 76
30 V/DC
INTENDED USE
Analogue fixed measuring instruments are intended for installation in switching cabinets or
display panels. The installation occurs directly without external components; appropriate pre-
resistors are already integrated in the circuit. Only in integrated status they may be put into
operation. The suitable regulations are to be observed. The fixed measuring instruments are
available with different measurement ranges. The scale needle can be adjusted precisely
with the front screw. The fixed measuring instrument may only be used in voltage ranges
<75 V/DC. Observe the technical data for this! Assembly and installation may only be carried out
by a specialist, who is familiar with the relevant regulations and the ensuing risks.
The device must not be used in damp interiors or outdoors in the open air.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged.
In addition, improper use can cause hazards such as short circuiting, fire, electric shock etc.
Read the instructions carefully and keep them. Make this product available to third parties only
together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
DELIVERY CONTENT
• Meter
• Mounting material
• Operating instructions
SAFETY INSTRUCTIONS
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information
on proper handling in this manual, we assume no liability for any resulting
personal injury or damage to property. Such cases will invalidate the warranty/
guarantee.
a) Persons / Product
• The fixed measuring instrument must not be used for medical purposes.
• Be especially cautious in dealing with voltage >35 V/DC. Already at this voltage you
can get a life-threatening electric shock when touching electric lines.
• The device is not a toy. Keep it out of the reach of children and pets.
• Do not leave packaging material lying around carelessly. These may become
dangerous playing material for children.
• Protect the product from extreme temperatures, direct sunlight, strong jolts, high
humidity, moisture, flammable gases, vapours and solvents.
• Do not place the product under any mechanical stress.
• If it is no longer possible to operate the product safely, take it out of operation and
protect it from any accidental use. Safe operation can no longer be guaranteed if
the product:
- is visibly damaged,
- is no longer working properly,
- has been stored for extended periods in poor ambient conditions or
- has been subjected to any serious transport-related stresses.
• Please handle the product carefully. Jolts, impacts or a fall even from a low height
can damage the product.
• Also observe the safety and operating instructions of any other devices which are
connected to the product.
• De-energise the electric system before installing the measuring instrument.
b) Miscellaneous
• Consult an expert when in doubt about operation, safety or connection of the
device.
• Maintenance, modifications and repairs are to be performed exclusively by an
expert or at a qualified shop.
If you are not sure about the correct connection or use, or if questions arise which are not
covered by these operating instructions, please do not hesitate to contact our technical support
or another qualified specialist.
Voltcraft®, Lindenweg 15, D-92242 Hirschau, Tel. +49 180/586 582 7.
EXPLANATIONS OF SYMBOLS
At the scale's face different symbols are attached, that have the following significance:
VERSION 01/13
Installation position vertical
Direct voltage/-current (DC)
INSTALLATION
Mount the measuring instrument with the assembly material included in a pre-assembled
rectangular front panel opening. Carefully attach the fixed measuring instrument. You can get
the corresponding dimensions (in mm) from the following sketch.
9.3 11.0
11.0
CONNECTION
In order to ensure a correct start of operation, you should read these operating
instructions including the safety instructions thoroughly and attentively before
using the device.
Do not connect when the wires are live.
Connection of the voltage measuring instruments (item no. 103075 and 103076) is done by
means of parallel connection. Connection of the current measuring instruments (item no.
103073 and 103074) is done by means of series connection. Connect the fixed measuring
instrument to the two screw terminals on the back as shown.
Parallel connection for V
DISPOSAL
Electronic devices are recyclable waste and must not be disposed of in the household
waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
TECHNICAL DATA
Item no.:
Measurement range:
Accuracy class:
Movement:
Operating conditions:
Storage conditions:
Weight:
Legal notice
These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7
(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2013 by Voltcraft®
Accuracy class related to the scale
2.0
end value
Moving coil instrument
85.5
44.5
ø 3.0
ø 3.0
Series connection for A
10 30 73
10 30 74
10 30 75
5 A/DC
15 A/DC
15 V/DC
2.0
Moving coil
-25 to +55 °C, 20 – 95% RH
-40 to +70 °C, 20 – 95% RH
approx. 65 g
ø 3.0
ø 3.0
10 30 76
30 V/DC