Technical data
SURFACE MOUNT MAGNETIC CONTACT AMK 4 G2
Operating distance
: 50 mm, ± 6 mm
Permitted operating voltage : max. 40 V DC
Switching current
: max. 500 mA
Contact capacity
: max. 6 W or 6 VA
Transition resistance
: max. 0,15 Ohm
Breakdown voltage
: > 250 V
Connecting cable
: LIYY 4 x 0,14 mm² Cu tinned;
Inner conductor:
: white
Dimensions cable
: ø 3,2 mm, L 2 m
Dimensions contact housing : 146 x 50 x 16,5 mm
Protecting hose
: ø 6 x 9 mm steel
Magnet
: ø 12 x 55 mm AlNiCo 5, axial polarized
Dimensions magnet housing : 66 x 40 x 35 mm
Housing material
: Polyamid GF
Colour
: grey
Operating temp. range
: - 40 °C to + 70 °C
Protection class
: VdS-environmental class III, IP 67,
Extend of Delivery
• 1 shutter contact with protecting hose
• 1 shutter magnet
• Mounting instructions
Description
Normally the surface mount magnetic contact is installed at rolling gates,
sliding gates, sweeping gates and so on.
The contact housing is mounted on the ground. The surface at the place of
installation must be smooth.
Only non-ferromagnetic screws must be used for mounting the surface mount
magnetic contact.
The design of the unit protects the circuit against weather and mechanical
influences from vehicles with latex tires. The connecting cable (4 wires) is
protected by a metal hose which is PVC coated.
The position of the magnet housing is given by the contact housing. Make
sure that the magnet housing fits to the marking on the contact housing.
The prefered mounting distance between contactand magnet-housing is
shown in the schematic of distance. Ferromagnetic parts disturb the magnetic
field of the surface mount magnetic contact. The area of approach and removal
changes in the schematic of distance. Find the normal switching area by
testing. The magnet should be fixed in the middle of the normal switch area
on principle.
One part of the surface mount magnetic contact is fixed at a door. When the
door is closed, a small movement can still exist. Take care of this tolerance.
After the mounting is finished, an electricalcontinuity check must be carried
out (ohmmeter).
CAUTION: The magnet loses a part of its field strength if it gets very hot
or through mechanical influences. This also can happen, if the
magnet is moved close to the area of another magnet.
Honeywell Commercial Security
Novar GmbH
Johannes-Mauthe-Str. 14
72458 Albstadt, Germany
www.honeywell.com
info.security.de@honeywell.com
Certificate holder:
LINK GmbH, Bahnhofsallee 59-61, 35510 Butzbach, Germany
suitable for LSA insulation
galvanized, PVC coated
EN-environmental class IIIA
Mounting Instructions
Item no. 031055
MA0002140
3418
Mounting
Schematic of distance
+ X
Operating
Tol.
distance (mm)
[mm]
A
50
± 6 mm
B
60
± 6 mm
Min. operating distance:
44 mm
Tol. in x:
± 3 mm
- X
Connecting cable
Connection
1
2
4
3
Before connecting, the wires must be electrically checked !
AMK 4 G2
G 191 565, Kl. B
D
EN 50131-2-6, Grad 2
GB
Magnet-housing
Contact-housing
A
B
Y
Safe area
Ruhebereich
A = approach / make distance
A = Näherungs-/ Einschaltabstand
B = removal / break distance
B = Entfernungs-/ Abschaltabstand
1
2
Technical changes
without prior notice
possible
3
4