1. Installation

1. Open the package and check if it contains all
components.
2. Hang the generator (horizontal) on a suitable place
in the desired area. The CO
placed more than 50 cm away from ceiling, wall or
other objects. Make sure that the CO
levelled correctly! If it is not hanged properly and
tilted for more than 30 °C, the generator will not
work due to tilt switch protection.
3. Do not place flammable goods near the CO
generator.
4. Connecting the CO
2
enclosed sealant or ask advice.
5. Connect the enclosed tubes to the reductor valve.
Connect one end to the CO
end of the tube to the gas bottle.
6. Open the gas supply. By coating the tube with soapy
water, you will be able to check the tube for any
leakage. In case of a leakage, you will see air
bubbles. Repair the leakage as soon as possible and
repeat the procedure. Ventilate the area.
7. Connect the supplied adapter to the CO
and a wall socket. Connect the adapters output to
the panel of the generator. Turn on the control
switch and check if the indicator light is turned on
and if the ignition has an pilot light (if so, then the
CO
generator operates as it should). Turn off the
2
control switch.
8. If the above steps went well you can turn on the
control switch to start up the generator.
NOTE: Because the generator will be ignited for the
first time, air will be blown from the tube. That is
why it can sometimes take a while before the
ignition is successful.

2. Startup

If the CO
generator is installed successfully, start
2
ignition by turning on the control switch. The
CO
generator operates according the following steps:
2
1. Turn on the control switch. Ignition will start
automatically and sparks can be seen between the
contacts.
2. The solenoid valve opens and gas will flow from the
burner.
3. The gas will ignite and all burners are turned on. The
gas supply to the CO
______________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
generator must be
2
generator is
2
2
generator. For this, use the
generator and the other
2
generator
2
generator is now successful.
2

3. Safety

If the burner does not ignite within 10-15 seconds, the
solenoid valve will close and the gas supply will be cut
off. An alarm will go off . Reset the CO
turning the control switch off and on. If the ignition is
successful, the generator will operate normally. If not,
the ignition mode will close the solenoid valve and an
audible alarm will be heard again

4. Shutting down

1. Turn of the control switch.
2. Close the gas bottle.
3. Remove the adapter from the wall socket.

5. Recommendations

The ideal CO
value for you area is dependent on
2
your type of crops.
Start with a low CO
2
Usually, a value higher than 1500 ppm is awaste.
Human beings who inhale too much CO
from headache and dizziness.
A CO
value higher than 5000 ppm is dangerous for
2
humans and animals. That is why we advise you to
use a suitable CO
controller when you are using a
2
CO
generator so that it is possible to adjust the
2
correct value to control the CO
automatically. Do not ventilate the area too much so
the CO
value can maintain in good condition.
2
The CO
generator must be operational during the
2
day. Therefore, it is rather pointless to add CO
during the night. For this reason, use a CO
controller with light sensor.
Do not touch the CO
because the exterior will get very hot, especially the
bottom.

6. Notes

1. Check if the CO
generator is not damaged. If so, DO
2
NOT use it.
2. Do not make any adjustments when the CO
generator is burning.
3. The colour of the flame must be blue.
4. Use the hook with chain to hang the CO
Make sure that part is strong enough to carry the
CO
generator.
2
generator by
2
value and increase slowly.
will suffer
2
generator
2
2
generator when operational
2
2
generator.
2
2
10