INSTALLATION AND OPERATION INSTRUCTIONS
The transformer with terminal box should be installed inside the room in a zone not subject to influence
of the raised humidity.
At that, it is not allowed in the course of installation and operation: lngress of splashes, rain drops,
Direct solar light,
lnstallation near to heating devices, other sources of heat.
The fire safety requirements should ba observed during installation and operation. Connection to the
electric power network should be carried out by one of two ways:
By means of an electric cable equipped with the standard plug for connection to the corresponding
socket integrated in the fixed wiring,
Through the switch with contact gaps at least 3 mm on all poles integrated in the fixed wiring. Regulator
connection to the electric power network should be carried out according to schemes shown on fig. 2, 3,
where:
Q1 - the external switch integrated in the fixed wiring,
XT1 -input terminal block with the integrated safety fuse in protective terminal box, XF1 - socket
integrated in the fixed wiring,
M1 - standard plug, T1 - the transformer,
XT2 - output block for connection of the fan with supply voltage of 12V,
B - fan with supply voltage of 12 V
Transformer,protective terminal box as well as output terminal block and downlead should be reliably
fixed on the basis of an insulation material
{The wood structure ls not consldered to ba a rellable lnsulator).
The terminal block XT2 should be protected against dust and moisture. 1t is not allowed, to place and fix
the terminal block XT2 on the conducting basis. lf the 1ransformer is placed in a box, the sufficient
ventilation should be provided in order to except its overheat.