Herunterladen Inhalt Inhalt Diese Seite drucken

Water Pipe Connection; Electric Connection - habitat et jardin Comfort 1436_103314 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 38

Water pipe connection

- The water flow through this machine needs to be driven by an auxiliary water
pump (Prepared by the user). The recommended pump specification-flux is
shown on the product specification and Max. lift ≥10m;
- Pipe length between heat pump and swimming pool should not be longer than
10m.
Noted: The drawing is just for demonstration, and layout of the pipes for reference only.

Electric connection

- Wiring must be handled by professional technician according to the circuit
diagram
- Connecting the heat pump to appropriate power supply and the voltage should
comply with the rated voltage of each model stated on the specification.
- Making sure the machine is earthed well.
- Setting up leakage protection according to local leakage standard (leakage
operating current ≤ 30mA).
- Protect the circuit with a suitable circuit breaker or fuse.
10

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Comfort 1436_103315Comfort 1436_103316

Inhaltsverzeichnis