Herunterladen Diese Seite drucken

Werbung

SE
.... 20
IT
.... 44
GB
.... 25
NL
.... 49
DE
.... 29
NO
.... 54
Original instructions
PA2500
ES
.... 34
PL
.... 59
FR
.... 39
RU
.... 64

Werbung

loading

Inhaltszusammenfassung für Frico PA2500

  • Seite 1 Original instructions PA2500 ..29 ..39 ..34 ..20 ..25 ..49 ..59 ..44 ..54 ..64...
  • Seite 2 PA2500 Introduktionssidorna består huvudsakligen av bilder. För översättning av de engelska texter som används, se respektive språksidor. The introduction pages consist mainly of pictures. For translation of the English texts used, see the respective language pages. Introduksjonssidene består hovedsakelig av bilder. For oversettelse av de engelske tekstene, se de respektive språksidene...
  • Seite 3 PA2500 PA2500 1026 / 1536 / 2026 1050 / 1560 / 2050 1026 / 1536 / 2026 90,5 min 500 1026 / 1536 / 2026 1050 / 1560 / 2050 Cu ø15 90,5 min 500 1050 / 1560 / 2050...
  • Seite 4 PA2500 Gland ø17,5 Gland ø17,5 Knock-out ø32,5 ø25,5 Knock-out ø20,5 Gland Knock-out ø17,5 Fig.2...
  • Seite 5 PA2500 TX20 Fig.3: Open the unit. Fig.4: Minimum distance.
  • Seite 6 PA2500 Mounting with wall brackets ø8 (3x) ø5 ø10 2 pcs PA2510 PA2515 2 pcs Fig. 6: Mounting with wall brackets PA2520 3 pcs...
  • Seite 7 PA2500 Accessories PA34TR15 PA2510, PA2515, 1 m PA2520, 1 m PA34TR20 PA2510, PA2515, 1 m PA2P15 PA2520, 1 m PA2P20 PA2PF15 PA2510, PA2515 PA2PF20 PA2520 PAMLK PA2500 PA2EF10 PA2510W PA2EF15 PA2515W PA2EF20 PA2520W PAWAK PA2500W PA34TR PA2P FHDN15 PA2500W PA2PF...
  • Seite 8 PA2500 Accessories SIRe SIReB SIReAC SIReAA SIReB SIReUR SIReRTX 70x33x23 mm SIReUR 114x70x50 mm SIReWTA SIReWTA SIReCJ4 SIReCJ6 SIReCC603 SIReCC605 SIReCC610 10 m SIReAC/SIReAA SIReCJ4/SIReCJ6 15 m SIReCC615 SIReCC640 40 m SIReCC403 SIReCC405 SIReCC410 10 m SIReCC415 SIReRTX SIReCC VLSP...
  • Seite 9 PA2500 PA2510E05 / PA2515E08 / PA2520E10 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 10 PA2500 PA2510E08 / PA2515E12 / PA2520E16 SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 11 PA2500 PA2510A / PA2515A / PA2520A PA2510W / PA2515W / PA2520W SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 12 PA2500 PA2510E05YD / PA2515E08YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 13 PA2500 PA2520E10YD SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo...
  • Seite 14 PA2500 PAMLK, motor alarm board SUPPLY L N PE ID. pot. ACTUATOR ROOM H1 H2 N F1 F2 F3 Heating Motor/trafo N F1 F2 F3...
  • Seite 15 PA2500 SIReB Basic PA2500 A PA2500 E SIReUB1 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) SIReCC6XX (max 50 m) SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m) SIReB1/B2/B1EC...
  • Seite 16 PA2500 SIReB Basic PA2500 W SIReUB1 SD230 SIReRTX SIReB1/B2/B1EC 230V~ (optional) ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX L=2m (max 50 m) L=1,5m SIReCC6XX (max 50 m) SD230 SIReB1/B2/B1EC 230V~ ROOM Pot. Unit ID ACTUATOR SUPPLY SIReCC6XX (max 50 m)
  • Seite 17 PA2500 Output charts water PA2500 Supply water temperature:110 °C Water temperature: 110/80 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +35 °C* Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow drop air temp.
  • Seite 18 PA2500 Output charts water PA2500 Supply water temperature: 60 °C Water temperature: 60/40 °C Room temperature: +18 °C Room temperature: +18 °C Outlet air temperature: +32 °C Type Airflow Output Return Water Pressure Output * Outlet Water Pressure position water flow...
  • Seite 19: Technical Specifications

    PA2500 Technical specifications Voltage motor: 230V~ Ambient, no heat - PA2500 A Type Output Airflow* Sound Sound Voltage Amperage Length Weight power* pressure* motor motor [kW] [dB(A)] [dB(A)] [mm] [kg] PA2510A 900/1300 43/53 230V~ 1050 PA2515A 1250/2100 44/54 230V~ 1560...
  • Seite 20 Schrauben des Geräts entlang der Schiene in die Halterungsschlitze. (Abb. 6C) Ist die Einsatzbereich Halterung einmal gebogen worden, muss Der PA2500 ist für Installationshöhen bis sie ersetzt werden, sofern sie über 45° zu 2,5 Metern geeignet. Der Luftschleier ist zurückgebogen wird.
  • Seite 21 Beachten Sie, dass für das Gerät ein ermöglicht, da das Gerät nicht geöffnet werden Regelventil vorgeschaltet sein muss, siehe muss. Sollte ein externer Filter verwendet Ventilsatz von Frico. werden, ist der interne Filter zu entfernen. Das Wasserheizregister wird an der Geräteoberseite mithilfe eines glatten...
  • Seite 22 PA2500 Sollte er aufgrund von Überhitzung ausgelöst 2. Die Frontklappe wird entfernt, indem die werden, setzen Sie ihn wie folgt zurück: Schrauben an der Geräteoberseite gelöst 1. Schalten Sie die Stromversorgung über den werden und die gebogene Kante an der voll isolierten Schalter ab.
  • Seite 23 PA2500 Austauschen des Heizregisters (W) FI-Schalter (E) 1. Schalten Sie die Wasserversorgung des Sollte die Installation durch einen FI-Schalter geschützt sein, die beim Anschließen des Geräts Geräts ab. ausgelöst wird, kann dies mit der Feuchtigkeit 2. Lösen Sie die Anschlüsse des Heizregisters.
  • Seite 24 Airflow [m Luchtstroom Output* [kW] Leistung Return water temperature [°C] Rücklaufwassertemperatur Water flow [l/s] Wassermenge Pressure drop [kPa] Druckverlust ) Empfohlene Ausblastemperatur für angenehmen Komfort und optimale Leistung. ) Nennleistung bei angegebener Vor- und Rücklaufwassertemperatur. Weitere Berechnungen finden Sie auf www.frico.se.
  • Seite 25 Main offi ce Frico AB Tel: +46 31 336 86 00 Box 102 SE-433 22 Partille mailbox@frico.se Sweden www.frico.se For latest updated information and information about your local contact: www.frico.se...