XRE
Output
Max. Flow
Max. Press
(1)
Code
-
[GPH]
[l/h]
[psi]
2
16
60.6
150
3
32
121.1
100
4
53
200.6
60
(1) Maximum flow rate at maximum pressure. Maximum flow rate may be higher at lower pressures.
(2) 175 psi (12 bar) max. with 1/4"x1/2" reinforced PVC hose or 6x12mm reinforced PVC hose;
150 psi (10 bar) max. with 3/8" PE tube or 8mm PE tube.
(3) High viscosity option 150 psi (10.3 bar).

4.0 Installation

The pump can be mounted in one of two ways:
Suction conditions can affect the performance of the pump. Consult your distributor for
additional information.
Your metering pump must be mounted so that the suction and discharge valves are vertical.
When pumping downhill or into a low or no pressure system, a backpressure / anti-syphon
device should be installed to prevent over pumping or syphoning.
False Flooded Suction
Max.
Stroke
Stroke
Standard
Length
Speed
Liquid
Ends
[bar]
[mm]
[SPM]
10.3
6
198
50
6.9
3.6
200
50
4.1
6
184
50
Flooded Suction (Figure 1) [ideal installation]; or
Suction Lift (Figure 2)
INCORRECT
Max. Viscosity
High Viscosity Liquid Ends
SLOW
w/o
Polymer
MODE
SLOWMODE
20%
[cP]
2000
1000
3000
2000
500*
2000
2000
500*
2000
*Up to 20% flow reduction
3
INSTALLATION
Max.
Max.
Suction
Suction
Inlet
SLOW
Lift
Pressure
MODE
50%
[ft]
[m]
[psi]
[bar]
2000
13.1
2
30
500*
6.5
2
30
1000
6.5
2
30
CORRECT
Min. Pressure
Differential
(Suction to
Discharge)
[psi]
[bar]
2
30
2
2
30
2
2
30
2

Werbung