INSTALLATION INSTRUCTIONS
Technical Data / Technische Daten
Isolating spark gap, Class N acc. to
EN 62561-3
No. 923 019
Type EXFS KU, Part
Ex component:
II 3 G Ex nC IIC T4 Gc
Certificates:
DEKRA 11ATEX0146 X
IECEx DEK 11.0063X
(s. www.dehn.de)
Standards:
for ATEX: EN 60079-0: 2009
EN 60079-15: 2010
for IECEx: IEC 60079-0: 2007
IEC 60079-15: 2010
Ambient temperature range:
-20°C ... +60°C for temperature class T4
Example: Insulating piece / Beispiel an einem Isolierstück
Isolating spark gap / Funkenstrecke
Fig.2
Insulating
piece
/Isolierstück
Insulation
Isolierung
S
L
B
10 Nm
A
A
B
Federring
Note:
The spark gap can be tested for correct operation by means of an insulation
resistance meter (strictly follow the instructions for use of the insulation
resistance meter). The spark gap may only be tested (measured) in an
uninstalled state and outside the Ex zone (R
≥ 500 k
iso
can be made in agreement with the operator.
Hinweis:
Die Funkenstrecke kann mit einem Isolationsmessgerät auf Funktion geprüft
werden.
Die Überprüfung darf nur unter Beachtung der Bedienungsanleitung des
Isolationsmessgerätes erfolgen. Die Überprüfung (Messung) darf nur im
ausgebauten Zustand der Funkenstrecke und außerhalb der Ex-Zone erfolgen.
(R
≥ 500 k
Ω /
500 V). Ausnahmen sind in Abstimmung mit dem Betreiber
iso
möglich.
Rated power-frequency withstand voltage/
Bemessungs-Stehwechselspannung
Lightning impulse sparkover voltage/ (1,2/50 µs )
Ansprech-Blitzstoßspannung
Lightning impulse current/ (10/350 µs )
Blitzstoßstrom
Operating temperature range/
Betriebstemperaturbereich
Degree of protection/
Schutzart
Connection/
Anschlussgehäuse
Installation notes / Installationshinweise
Voltage drop at connecting cables depending on the cable length and the impulse current steepness.
Spannungsfall an Anschlußleitungen in Abhängigkeit von der Leitungslänge und der Steilheit des Stoßstroms.
Connecting Cable Length [m] /Länge Anschlussleitung [m]
H
Voltage Drop [kV] at 10 kA/µs, LPL I / Spannungsfall [kV] bei 10 kA/µs, BSK I
Voltage Drop [kV] at 7.5 kA/µs, LPL II / Spannungsfall [kV] bei 7.5 kA/µs, BSK II
Voltage Drop [kV] at 5 kA/µs, LPL III / Spannungsfall [kV] bei 5 kA/µs, BSK III
The sum of the voltage drop at the connecting cables and the lightning impulse sparkover voltage must not exceed the insulation strength of the test joint.
Die Summe aus Spannungsfall an den Anschlussleitungen und der Ansprech-Blitzstoßspannung darf die Isolationsfestigkeit der Trennstelle nicht überschreiten.
Note: Observe the requirements of AfK recommendation No. 5.
Hinweis: Die Vorgaben entsprechend der AfK-Empfehlung Nr. 5 (07/2010) sind zu beachten.
Schraube M 10
Requirements on the connecting cables:
Ω /
500 V). Exceptions
Suitable connection points on pipelines are:
U
300 V
w/AC
U
≤ 2,5 kV
r imp
I
50 kA
imp
-20° ... + 80° C
IP 67
M 10
Capable of carrying lightning currents
No ignition sparks
Situated in parallel and as close as possible to the insulating piece
Connected using the shortest path
Protected against accidental bridging (for example by means of tools)
Welded lugs, pins
Threaded holes in the flanges to receive bolts
Observe connection clamps / pipe clamps / absence of ignition sparks
Publication No. 1186 UPDATE 11.14 Mat. No. 3000229
Fig.1
L ~ 3150
0,10 0,20 0,30 0,50 0,75 1,00 1,25 1,50
1,0
2,0
3,1
5,1
7,6
10,1
0,8
1,5
2,3
3,8
5,7
7,6
0,5
1,0
1,5
2,5
3,8
5,1
Anforderung Anschlusstechnik
• blitzstromtragfähig,
• zündfunkenfrei,
• unmittelbar parallel und eng am Isolierstück angeordnet,
• auf kürzesten Weg angeschlossen,
• gegen zufälliges Überbrücken (z.B. durch Werkzeuge) gesichert
Geeignete Anschlusspunkte an Rohrleitungen sind
• angeschweißte Fahnen, Bolzen
• Gewindebohrungen in den Flanschen zur Aufnahme von Schrauben
• Anschlußschellen / Bandrohrschelle / Zundfunkenfreiheit beachten
© COPYRIGHT 2014 DEHN + SÖHNE / proected by ISO 16016
2,00 3,00
4,00 4,25
12,6
15,1
20,2
30,2
40,3 42,8
9,5
11,4
15,2
22,7
30,3 32,2
6,3
7,6
10,1
15,1
20,2 21,4
p.t.o.
Safety
Instructions

Werbung

loading

Inhaltszusammenfassung für Dehn EXFS L100

  • Seite 1 Isolationsmessgerätes erfolgen. Die Überprüfung (Messung) darf nur im p.t.o. ausgebauten Zustand der Funkenstrecke und außerhalb der Ex-Zone erfolgen. ≥ 500 k Ω / 500 V). Ausnahmen sind in Abstimmung mit dem Betreiber Safety möglich. © COPYRIGHT 2014 DEHN + SÖHNE / proected by ISO 16016 Instructions...
  • Seite 2 DEHN + SÖHNE GmbH + Co.KG Publication No. 1186 UPDATE 11.14 Mat. No. 3000229 Hans-Dehn-Str. 1 Postfach 1640 92306 Neumarkt www.dehn.de Germany info@dehn.de Tel: +49 9181 906-0 Fax: +49 9181 906-1100 Veiligheidsaanwijzingen Avvertenze per la Instrucciones de Consignes de sécurité...
  • Seite 3 INSTALLATION INSTRUCTIONS Publication No. 1186 UPDATE 11.14 Mat. No. 3000229 EC Declaration of Conformity © COPYRIGHT 2014 DEHN + SÖHNE / protected / by ISO 16016...
  • Seite 4 INSTALLATION INSTRUCTIONS Publication No. 1186 UPDATE 11.14 Mat. No. 3000229 EC Declaration of Conformity © COPYRIGHT 2014 DEHN + SÖHNE / protected / by ISO 16016...