installation and maintenance sheet
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the lamp. The appliance must not be tampered with or
transformed and it must be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee.
The company cannot be held responsible for damage caused by incorrect assembly.
Ø 140
• max wind exposed surface: 0.06m
• weight: MH35 = 5.55Kg
MH70 = 6.0Kg
halogen = 4.45Kg
• mounting height: any
pict. 1
PL bracket
50%
50%
PL
Accessories
• It is possible to provide the fixture with accessories that allow to obtain light blades, coloured beams and other effects, as shown in the product catalogue.
Relamping - Maintenance:
• respect fully type and power of lamp as shown on the label. Read carefully the instructions of the lamp manufacturer for proper lamp use. The relamping must be done with
maximum attention avoiding to dirt the sealing gasket and its contact surface. It is therefore necessary, before opening the fixture, to clean it accurately. If the gasket is
damaged, deformed or not in perfect condition it is necessary to change it.
• it is essential to do a frequent cleaning of the glass and of the outer surface of the fixture to avoid build up of mud and dirtiness resulting in dangerous overheating due to
incorrect light and heath dissipation. Clean the glass screen carefully by removing limescale by means of a scraper.
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number
that recognizes the fixture
250
110
2
cable gland
pict. 2
65%
35%
HAVELLS SYLVANIA EUROPE LTD
Avis Way Newhaven East Sussex BN9 0ED
www.havells-sylvania.com
scope/W (metal halide & halogen)
Features - meaning of the symbols shown on the label:
suitable for exterior or interior free air operation
mounting on wall
IP66 totally dust-proof - water-proof on ship's decks
installation on normally inflammable surfaces allowed
minimal distance between fitting and lighted object
0,3m
Classe I
simple insulation: earth required
replace the damaged protective glass screen
getting rid of as urban waste is forbidden
separate collection is mandatory when the product is at the end of its life
Installation:
A
• for outdoor locations it is mandatory to use (CEI EN 60598-1;
CEI
20-40/CENELEC
rubber cable type H07RN-F with diameter between 9 and 12mm.
PVC insulated cables or with outer PVC cover or any cable different from the
one here prescribed are not allowed.
• To open the fixture unscrew the two screws of the body (pict.1).
• Loosen the three screws "A" so that the control gear block can be removed
(pict.2)
• Use the base to mark the wall fixing points. Then fix the base following the
"upward" position marked on the base itself.
• Put the control gear block again in its position tightening it with the three
screws "A". Connect the cables to the terminal respecting the polarities, then
tighten carefully the cable gland and the cable gland head (pict. 2)
35%
65%
product in compliance with the requirements
of the European Community Directories
HD516S1)
a
three
core
Adjusting the light beams
The fixture is supplied with symmetric light emission,
same one for both directions. It is possible to change this
emission as follows:
Asymmetric beam
• To obtain an asymmetric beam pointed towards the
fixing wall or externally shift the lampholder bracket as
shown in the side pictures.
Mainly upward or downward beam
• To obtain a beam pointed mainly upward or downward
shift the lampholder as shown in the side pictures.
N.B.: adding the two adjustments it is thus possible
to obtain, for example, the asymmetric beam
towards the fixing wall with 50% distribution or
65% distribution upward or downward, etc.
• Place the lamp in respecting the power shown on the
label and make sure of the perfect position of the lamp
in its lampholder. A bad position produces wrong light
beams.
• Re-screw the body on the base carefully, without
knocking against the lamp. Make sure that the gasket is
in good condition and that it is clean.
IS13112
flexible
neoprene

Werbung

loading

Inhaltszusammenfassung für Sylvania CONCORD scope/W Serie

  • Seite 1 Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that recognizes the fixture HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED...
  • Seite 2 Contrôle qualité: Pour toute réclamation, nous vous prions de bien vouloir contacter notre société ou notre organisation de vente, en citant le numéro de commande et le numéro qui contremarque l’appareil. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED...
  • Seite 3 Kalkablagerungen können mit einem Schaber entfernt werden. Qualitätskontrolle: Sollten Sie Reklamationen haben, wenden Sie sich an unsere Firma oder an unsere Verkaufsorganisation unter Angabe des Bestelldatums und der Kennummer des Geräts. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED www.havells-sylvania.com...