installation and maintenance sheet
NB: These assembly instructions must be given to end users for correct maintenance and so that they know how to change the bulb. The appliance must not be tampered with or
transformed and it must be installed and used as supplied and in compliance with the National Rules on Installations. Any non-compliant installations will invalidate all forms of guarantee.
The company cannot be held responsible for damage caused by incorrect assembly.
Pharus/R1
Pharus/R2
Ø
Ø
R1
100
100
Ø
Ø
R2
180
180
pict. 3
pict. 5
pict. 7
pict. 10
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number
that recognizes the fixture.
HAVELLS SYLVANIA EUROPE LTD
Avis Way Newhaven East Sussex
BN9 0ED
www.havells-sylvania.com
Pharus/S1
S1
100
100
pict. 2
pict. 1
pict. 4
pict. 6
Ø min 8.5 mm
Ø max 12 mm
pict. 8
Features - meaning of the symbols shown on the label:
suitable for exterior free air operation - pole mounting
IP66
IK10 shock resistance according to EN50102
Class I
RISK GROUP 2
CAUTION: Possibly hazardous optical radiation emitted from this product.
Do not stare at operating lamp. May be harmful to the eye.
INSTALLATION:
• fix the base to the ground, with 4 M8 screw anchors or with the base plate with
log bolts (picture 1 and drawing A)
• tighten the two dowels as in the figure so that they are completely recessed
and pull out the head of the fixture from the pole (picture 2)
• remove the two dowels by completely unscrewing
electrical block sliding out the diffuser screen (picture 3)
• for the fluorescent version only: unscrew the two stud bolts and remove the
anti-glaring grid (picture 4)
• unscrew the screws, extract the electrical block from the body (picture 5) and
do the wiring, respecting the polarities; tighten the cable clamp plate (picture
6).
• fix the wiring to the body, tighten the cable clamps closing the one that is not
used with the cap supplied.
• repeat the steps of 4-3-2 in reverse order.
• slide the pole into the base and tighten the four screws (pictures 7 and 8)
For outdoor installation, flexible
(CEI EN 60598-1; CEI 20-40/CENELEC HD 516 S1) of the H07RN-F
Ø min 7.5 mm
type must be used. The cable diameter must be between 8 and 12mm.
Ø max 8.5 mm
PVC
insulated
cables
different
Proceed as in pict.9 for a correct coupling of cable/cable gland.
pict. 9
RELAMPING - MAINTENANCE:
• cut off power from the mains before carrying out any type of maintenance.
Respect fully type and power of lamp as shown on the label. Read carefully
the instructions of the lamp manufacturer for proper lamp use. The relamping
must be done with the utmost care avoiding to dirty the sealing gasket and
its contact surface. Before opening the fixture it is therefore necessary to
clean it accurately. If the gasket is deformed and not in perfect conditions it is
necessary to change it.
• to change the bulb, unscrew the dowels and lift up the cover of the appliance
(pictures 10 and 11).
RELAMPING
• to replace the LED circuit or connecting cable, you must contact our company
pict. 11
or our sales organization.
product in compliance with the requirements
of the European Community Directories
totally dust-proof
jet-proof from any direction
installation on normally inflammable surfaces allowed
heavy duty: can withstand impacts up to 6.5 Nm
simple insulation: earth required
replace the protection screens if damaged
getting rid of as urban waste forbidden
separate collection is mandatory when
the product is at the end of its life
neoprene rubber
cables
or
with
outer
from
the
one
here
prescribed
IS13181
Pharus
them and open the
tri-polar cable
PVC
cover
or
anyhow
are
not
allowed.

Werbung

loading

Inhaltszusammenfassung für Sylvania Concord Pharus Serie

  • Seite 1 Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that recognizes the fixture. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED www.havells-sylvania.com...
  • Seite 2 Contrôle qualité: Pour toute réclamation, nous vous prions de bien vouloir contacter notre société ou notre organisation de vente, en citant le numéro de commande et le numéro qui contremarque l’appareil. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED www.havells-sylvania.com...
  • Seite 3 Unternehmen oder an unsere Vertriebsorganisation. Qualitätskontrolle: Sollten Sie Reklamationen haben, wenden Sie sich an unsere Firma oder an unsere Verkaufsorganisation unter Angabe des Bestelldatums und der Kennummer des Geräts. HAVELLS SYLVANIA EUROPE LTD Avis Way Newhaven East Sussex BN9 0ED...