TIPS TO RECEIVE THE MOST ACCURACTE RESULTS
A) Wait at least 15 minutes after your last sip of alcohol.
Do not eat, drink, or smoke during that time.
B) Do not open the casing.
C) Do not keep the breathalyzer in cold, hot, moist, or badly
ventilated places.
D) Keep the breathalyzer out of the reach of children.
E) Conduct three inlet tests after long storage before
conducting the actual alcohol test.
F) Do not drop the breathalyzer.
G) Change the battery if it is depleted. Diminished battery
capacity leads to incorrect test results.
H) Do not conduct tests in loud (sound waves disrupt the
sensor), drafty, or poorly ventilated places.
I) After a test result of 1.00 per mill (per mill = EU setting) /
0. 1 0% BAC (% BAC = US setting) / 0.50mg/L (mg/L = UK
setting) or higher the sensor needs rest time. In this case
wait at least three minutes before starting the next test.
J) Do not conduct tests in very cold, very hot, or an
unventilated, smoky ambience.
K) Store the breathalyzer in a way to avoid penetration by
dust or liquids.
L) Blowing too hard may cause damage to the sensor as
saliva flows into it.
PREPARATION FOR THE TEST
1. Slide the battery compartment cover (on the back of the
unit) down and insert 3 AAA (alkaline, 1.5 V) batteries into
the battery compartment. When inserting and replacing old
batteries with new ones, always observe the polarity (+/-) of
the batteries.
2. Place a mouthpiece on the side opening for attaching the
mouthpieces (= the opening on the left side of the front of
the unit). Make sure that the mouthpiece is tight. Use a new
mouthpiece for each test person (for hygienic reasons and
to maintain the accuracy of the measurement, as a used
mouthpiece could contain residual carbon inside).
21
CONDUCTING THE MEASUREMENT
1. Sensor initialization
Turn on the device by pushing the Power button for
2 seconds. The sensor initialization will start automatically
and reset the sensor into a better working state. The display
shows the following picture:
Note: The sensor initialization time is determined
dynamically.
If the device was not used for a long period of time,
the initialization time will be longer.
During the use of the device, the sensor initialization
time depends on the last test concentration. If the
last test result was high, the initialization time will be
longer in order to reset the sensor and make the test
result more accurate, but the longest initialization time
won`t exceed 90 seconds.
Tip: Alarm level setting
During the sensor initialization mode, you can keep pressing
the "M" button for 2 seconds and so you can enter the alarm
level setting mode. Shortly press the "M" button to select
the alarm level b2, b3, b5 or b8. After the selection you can
press the power button to start a new test.