BLITZDUCTOR BSP
Basic circuit diagrams / Prinzipschaltbilder
BXT BAS
Part No. 920 300
BXT BAS
protected
1 2 3 4
4´ 3´ 2´ 1´
BSP M4... / M2...
1 2 3 4
4´ 3´ 2´ 1´
BSP M4 BD HF XXX
Part No. 926 XXX
1
2
protected
3
4
IEC 60417-6182:
Installation,
electrotechnical expertise
www.dehn.de
www.dehn-international.com
BSP M4 BD XXX
Part No. 926 XXX
1
2
protected
3
4
UL requirements
1. These modules are intended for ordinary indoor use on communication loop circuits that are isolated from the Public Switched
Telephone Network.
2. The protector module shall be secured to the compatible protector base before applying power to the communication loop.
3. The protector base shall be secured to a compatible DIN Rail ground bar using the methods described in this instruction.
4. Proper grounding continuity shall be determined.
5. If a replacement module is needed, deactivate power to the communication loop and only use a Listed protector module having
the same rated voltage breakdown range.
6. Please install the protector modules in accordance with the applicable requirements of the National Electrical Code, Article 800
or other applicable local codes.
7. Screw Terminal Ratings with the applicable wire gauge sizes shall be noted.
8. The maximum circuit current for UL 497 B application is limited to 100 mA
Tabulation Strike voltage in accordance with UL 497 B (Protectors for Data Communication and Fire Alarm Circuits)
Strike voltage 100 V / s
Blitzductor BST Series ML4
Type
Part No.
line to ground
line to line
line 1/1' to line 2/2'
line 3/3' to line 4/4'
min.
max.
min.
max.
926 320
13,4 V
17,0 V
BSP M4 BE 5
6,7 V
8,5 V
926 322
33,0 V
37,5 V
BSP M4 BE 12
16,5 V 18,7 V
70 V
83 V
BSP M4 BE 24
926 324
35 V
42 V
72 V
133 V
BSP M4 BE 48
926 325
59 V
67 V
72 V
173 V
BSP M4 BE 60
926 326
72 V
97 V
182 V
446 V
BSP M4 BE 180
926 327
182 V
224 V
6,7 V
8,5 V
926 340
70 V
110 V
BSP M4 BD 5
926 342
16,5 V 18,7 V
BSP M4 BD 12
70 V
110 V
926 344
35 V
42 V
BSP M4 BD 24
70 V
110 V
926 345
59 V
67 V
BSP M4 BD 48
70 V
110 V
926 346
72 V
87 V
BSP M4 BD 60
70 V
110 V
182 V
224 V
BSP M4 BD 180
926 347
182 V
278 V
7,5 V
10,0 V
BSP M4 BE HF 5
926 370
7,5 V 10,0 V
7,5 V
11,0 V
BSP M4 BD HF 5
926 371
70 V
110 V
36 V
43 V
BSP M4 BD HF 24
926 375
70 V
110 V
BSP M4 BE HF XXX Part No. 926 XXX
1
2
protected
3
4
Tabulation Strike voltage in accordance with UL 497 B (Protectors for Data Communication and Fire Alarm Circuits)
Surge voltage 100 V / µ s
BSP Series ML2 Signal lines 1/1' and 2/2'
line to line
line to ground
Type
line 1/1' to line 2/2'
line 3/3' to line 4/4'
BSP M2 BE 5
min.
max.
min.
max.
BSP M2 BE 12
6,7 V
9,0 V
13,4 V
18 V
16 V
19 V
BSP M2 BE 24
33 V
38 V
35 V
45 V
70 V
90 V
BSP M2 BE 48
59 V
70 V
118 V
140 V
BSP M2 BE 60
72 V
90 V
144 V
180 V
BSP M2 BE 180
182 V
250 V
182 V
500 V
BSP M2 BD 5
70 V
550 V
6,7 V
9,0 V
BSP M2 BD 12
70 V
550 V
16 V
19 V
BSP M2 BD 24
70 V
550 V
35 V
45 V
BSP M2 BD 48
70 V
550 V
59 V
70 V
BSP M2 BD 60
70 V
550 V
72 V
90 V
BSP M2 BD 180
182 V
550 V
182 V
250 V
BSP M2 BE HF 5
7,5 V
11,0 V
7,5 V
11,0 V
BSP M2 BD HF 5
70 V
550 V
7,5 V
11,0 V
BSP M2 BD HF 24
70 V
550 V
36 V
47 V
Blitzductor BSP Series ML2 Shielding line 3/3' and 4/4'.
For all types of BSP Series ML2 the lines 3/3' and 4/4' are shorted to ground
1685 / 03.19 / 59863
BSP M4 BE Part No. 926 XXX
1
2
3
4
Strike voltage 100 V / s
Surge voltage 100 V / µ s
Part No.
line 1/1' and 2/2'
line 1/1' to line 2/2'
line 1/1' and 2/2'
to ground
to ground
min.
max.
min.
max.
min.
max.
6,7 V
8,5 V
6,7 V
9,0 V
926 220
13,4 V
17,0 V
16,5 V
18,7 V
16 V
19 V
926 222
33,0 V
37,5 V
35 V
42 V
70 V
83 V
35 V
45 V
926 224
59 V
67 V
72 V
133 V
59 V
70 V
926 225
72 V
90 V
926 226
72 V
97 V
72 V
173 V
182 V
250 V
926 227
182 V
224 V
182 V
446 V
70 V
110 V
70 V
550 V
926 240
6,7 V
8,5 V
70 V
110 V
70 V
550 V
926 242
16,5 V
18,7 V
70 V
110 V
35 V
42 V
70 V
550 V
926 244
70 V
110 V
59 V
67 V
70 V
550 V
926 245
70 V
550 V
926 246
70 V
110 V
72 V
87 V
182 V
550 V
926 247
182 V
278 V
182 V
224 V
7,5 V
10,0 V
7,5 V 11,0 V
926 270
7,5 V
10,0 V
70 V
110 V
70 V
550 V
926 271
7,5 V
11,0 V
70 V
110 V
36 V
43 V
70 V
550 V
926 275
© COPYRIGHT 2019 DEHN SE + Co KG protected by ISO 16016
protected
line 1/1' to line 2/2'
min.
max.
13,4 V
18 V
33 V
38 V
70 V
90 V
118 V
140 V
144 V
180 V
182 V
500 V
6,7 V
9,0 V
16 V
19 V
35 V
45 V
59 V
70 V
72 V
90 V
182 V
250 V
7,5 V
11,0 V
7,5 V
11,0 V
36 V
47 V

Werbung

loading