Herunterladen Inhalt Inhalt Diese Seite drucken

Overview Of Faults Indication On The Display Of The Legadrive - Hettich LegaDrive Comfort 9 277 919 Montageanleitung

Handschalter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Overview of faults indication on the display of the
Bedienungsanleitung
LegaDrive handset
The display shows E + a fault number.
Possible cause
An internal fault has occured in the control unit.
No.
Possible cause
00
Internal fault on channel 1
01
Internal fault on channel 2
02
Internal fault on channel 3
12
Fault on channel 1
13
Fault on channel 2
14
Fault on channel 3
24
Motor M1 overcurrent
25
Motor M2 overcurrent
26
Motor M3 overcurrent
36
Plug detection on motor socket M1
37
Plug detection on motor socket M2
38
Plug detection on motor socket M3
48
Motor group 1 overcurrent
49
Motor group 2 overcurrent
55
Motor group 1 cannot be synchronised
56
Motor group 2 cannot be synchronised
60
Collision detection
61
Motor changed
62
Control unit overcurrent
67
Voltage too high
70
Changed drive configuration
81
Internal fault
93
Cascading fault
16
16
Hettich Marketing- und Vertriebs GmbH & Co. KG · Gerhard-Lüking-Straße 10 · 32602 Vlotho · Telefon +49 5733 798-0 · www.hettich.com
Hettich Marketing- und Vertriebs GmbH & Co. KG · Vahrenkampstraße 12 -16 · 32278 Kirchlengern · Téléphone + 49 52 23/77-0 · www.hettich.com
Remedy
Proceed as described in the following fault list.
Remedy
Switch the control unit o.
Contact customer service.
Unplug the control unit. Rectify the external short circuit.
Or:
Plug in the correcht lifting column at the socket concerned.
Put the control unit back into operation.
Remove the trapped objects from the adjustment zone.
If desk overloaded:
Remove load from desk.
Contact customer service.
Plug in the correct lifting column at the socket concerned.
Carry out a manuel reset (see 7).
Remove the trapped objects from the adjustment zone.
If desk overloaded:
Remove load from desk. Contact customer service.
Remove load from desk.
Carry out a manual reset (see 7).
If the fault is still shown after resetting, contact customer service.
Remove the trapped objects from the adjustment zone.
If desk overloaded:
Remove load from desk. Contact customer service.
Plug in the correct lifting column at the socket concerned.
Carry out a manuel reset (see 7).
Remove the trapped objects from the adjustment zone.
If desk overloaded:
Remove load from desk. Contact customer service.
Unplug the power supply cable and contact customer service.
See 9
Carry out a manual reset (see 7).
If the fault is still shown after resetting, unplug the power supply cable and plug it back
in again after a few seconds.
If the fault occurs on a regular basis, unplug the power supply cable and contact customer
service.
Check all cable connections and try to perform a reset.
If the reset is not possible, disconnect all control units from the electricity supply. Wait
for at least five seconds and reconnect all control units to the electricity supply. Try to
perform a reset again.
If a reset is still not possible after this, contact Customer Service.
Technik für Möbel

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis