3.1.1
Accumulator connector (J9)
The connector is for the backup accumulator.
Only use NEAT Accumulator, #NE31 14004-02.
3.1.2
Battery power switch (S1)
The battery power switch is used for turning on/off the battery
power in the unit, where I = On and O= Off.
3.1.3
Reset button (S2)
The reset button is used to send any of the 9 unit radio codes for
pairing with other NEAT radio units.
Radio code 1-8
E.g. to send radio code #3, press the reset button 3 times where the
time between each press is less than 2 seconds. The radio code is
sent 2 seconds after the third press is released.
Radio code 9
To send radio code #9, keep the reset button pressed for more than
2 seconds and then release. The radio code is sent 2 seconds after
the button is released.
3.2
LED
Picture 2. The LED on REPO+ II
At startup the LED blinks twice and then indicates as below.
• Fixed light - Power supply is OK.
• Blinking light - Power supply and/or battery failure.