Honeywell 45900438-Serie Anleitung Seite 2

Werbung

Code
Applicable for
V(R)46..
V(R)86..
101
Yes
103
Yes
104
Yes
107
No
109
No
110
No
111*
No
112
No
203**
Yes
204**
Yes
209**
No
213**
No
214**
No
301
Yes
404***
Yes
*
Only for VK41../VK81.. with venturi system
** With mounted cover
*** With mounted cover and terminal cap
Material of contacts
AgNi
Gold plated
values between brackets (..) valid for cos ϕ = 0.6
*
INSTALLATION, ADJUSTMENT
AND CHECKOUT
IMPORTANT
Be sure the product is suitable for your application,
otherwise consult Honeywell application
engineers.
Installer must be a trained experienced service
man Turn off gas supply before starting installation.
Disconnect power supply to prevent electrical
shock and/or equipment damage.
Do not turn sealed adjustment screw, the switch
point is factory set.
Adjustments should be made by qualified
persons only.
Mounting limitations
VK41../VK81.. gas controls provided with gas pressure
switch gives limitations in mounting position of valve/
venturi system.
VK41../VK81.. gas controls with venturi system should
be provided with gas pressure switch according fig. 5.
MU1R-9165 1211RB-NE
Table 1: Models gas pressure switch 45900438-
Switch point (mbar)
VK41..
ON
VK81..
No
15.5 ± 1
No
15.5 ± 1
No
12.5 ± 1
Yes
15.5 ± 1
Yes
15.5 ± 1
Yes
12.5 ± 1
Yes
12.5 ± 1
Yes
12.5 ± 1
No
15.5 ± 1
No
12.5 ± 1
Yes
15.5 ± 1
Yes
23 ± 1
Yes
23 ± 1
No
-
No
12.5 ± 1
Table 2: Electrical rating, contact resistance
Electrical rating
(resistive duty)*
250 Vac, 5 (0.5) A
24 Vac/dc, 100 (50) mA
Switch type
OFF
13 ± 1
SPST
13 ± 1
SPST
10 ± 1
SPST
13 ± 1
SPST
13 ± 1
SPST
10 ± 1
SPST
10 ± 1
SPST
10 ± 1
SPDT
13 ± 1
SPST
10 ± 1
SPST
13 ± 1
SPST
20.5 ± 1
SPST
20.5 ± 1
SPST
8 ± 1
SPDT
10 ± 1
SPST
Minimum electrical
Switch type
rating
24 Vac, 50 mA
5 Vac/dc, 10 mA
Mounting (See fig. 6., 7. and 8.)
Remove pressure tap screw from the inlet pressure
tap nipple of the gas control. (if applicable).
Position the gas pressure switch over the inlet pressure
tap nipple of the gas control. For VK41../VK81.. gas
controls hook-up the gas pressure switch behind metal
frame of coil assembly.
Put the connection screw with "O"-ring into the
inlet pressure tap nipple.
Tighten with a 9 mm box-spanner the connection
screw with a torque of 3 Nm. When inlet pressure tap
screw (on top of connection screw) has been used,
retighten the screw 1/4 turn beyond finger tight.
CAUTION
Do not turn connection screw more tight then
specified above because of possible damage.
2
Contact
Color of
material
sealing on
setting
screw
gold plated
red
AgNi
blue
AgNi
green
gold plated
red
AgNi
blue
AgNi
green
gold plated
yellow
AGNi
green
AgNi
blue
AgNi
green
AgNi
blue
AgNi
transparent
Gold plated
purple
AgNi
-
AgNi
green
Contact resistance
(initial)
SPDT or SPST
< 80 mΩ
SPDT or SPST
< 80 mΩ
Adjustable
pressure
range (mbar)
-
-
-
-
-
-
-
-
-
-
-
-
-
2 ... 17
-