Herunterladen Inhalt Inhalt Diese Seite drucken

stori Ecosun U+ Installations- Und Benutzerhandbuch Seite 7

Infrarot-strahlungsheizkörper 300, 600, 700, 850w
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1. Use
Flats, offices, schools, hospitals, shops, industry and agricultural premises, etc.
The panels can be installed on flammable materials.
2. Wiring
Power supply: 230V/50Hz
Protection class I
IP 44
The panel is fitted with a thermal fuse.
3. Installing
The panels are intended for vertical installation. In case of horizontal installation on the ceiling of a room, hang the panel
on a mounting frame, or using chains or cords.
The minimum distance of the panel front wall and lateral walls from inflammable objects is 10 cm.
Procedure — vertical mounting:
Mark the holes according to the table, drill out the holes, insert the dowels and drive the screw in to protrude
approx. 5 mm.
Always fix the panel on two upper locks, two lower locks serve to a reverse suspension of the panel.
Connect the lead-in cable to a fixed power distribution in accordance with the colour marking of wires.
Put the panel on the two upper locks.
Procedure – horizontal mounting
Position the mounting frame in the location where the panel is to be placed, using a pen, mark holes according to the
holes on the frame.
Drill the holes, insert the wall anchors and attach the mounting frame with the screws.
Connect the lead-in cable to the mains in accordance with the colour of the conductors.
Slide the panel into the mounting frame.
Ecosun
X (mm)
Y (mm)
300 U+
592
1192
600 U+
1192
700 U+
850 U+
1192
Fixing Frame
Ecosun
300 U+
600 U+
700 U+
850 U+
A (mm)
B (mm)
592
340
355
592
940
355
592
940
355
800
940
355
A (mm)
B (mm)
340
280
935
280
Thickness
30