  • DEUTSCH, seite 5
– Damage to the packaging that indicates that the component may have been
damaged
– Obvious damage to the component.
3. Send a damage report to the shipping company immediately.
4. The damage report must be received by the shipping company in writing within
six days following receipt of the component. We will be glad to help you if ne-
cessary.
Install AC overvoltage protection modules
↻ Lack of current and voltage ensured on the PV inverter.
1 Unfasten the housing cover of the PV inverter using the 6 screws and remove
carefully [
T_25]
2 Open the packaging of the AC SPD kits and remove components.
NOTE: Do not change the coding of the overvoltage protection modules.
There are 3 x MOV type modules and one GDT type module.
3 Insert overvoltage protection modules from left to right into the socket in ac-
cordance with the labelling on the board so that the top and bottom locking
latches engage.
4 Check that the modules are secure.
5 Remove SPD monitoring jumper for automatic monitoring.
6 Lift the housing cover onto the housing and loosely tighten the fastening
screws.
7 Tighten the housing cover using all 6 screws in diagonal pairs [
Nm]
» AC overvoltage protection is integrated with the PV inverter.