M O U N T I N G T H E A DA P T E R
ALWAYS ADHERE TO THE VEHICLE MANUFACTURER'S INSTRUCTIONS DURING THE BLEEDING PROCESS!
1.
Move the adapter along the wing to match the opening diameter of the equalising tank (Fig. 1).
1
2.
Place the universal adapter onto the brake fluid equalising tank and slide the wings
towards the tank.
3.
Now use the adjustment disc to fix the wings in place.
4.
Press the rubber cone with the adjustment screw against the opening on the equalising tank.
This ensures a flush connection between the adapter and the equalising tank (Fig. 2).
2
5.
Now connect the brake fluid filling line to the adapter.
6.
Continue the bleeding process according to the manufacturer's instructions.