Setting the threshold values
On the underside of the BiSens SW- Solar you will find multi-way
switches for setting the threshold values for wind and light; these
can be adjusted using a small screwdriver.
➙ light function is switched off
OFF
➙ extend in low light level
Step 1
Steps 2-14 ➙ intermediate levels
Light
➙ factory setting
Step 7
➙ extend at a high light level
Step 15
➙ change the mode
Function
➙ retract at low wind speed
Step 1
Steps 2-10 ➙ intermediate levels
Wind
➙ factory setting
Step 4
➙ retract at high wind speed
Step 11
Checking the light function (test mode)
Condition:
The blind is retracted.
The delay times are shortened in the test mode. You can then test
the travel movement of your system when the light threshold is
exceeded.
1. Press the UP button (wind symbol) for at least 3 seconds until
the transmission LED flashes.
The test mode stays active for 5 minutes but the LED goes out.
Risk of injury by the upward and downward travel
of the awning.
The test mode is active for 5 minutes. This time
cannot be shortened.
Keep away from the operating range of the system.
Warning!
2. Shine a torch (not an LED lamp) on the light sensor.
Specified light threshold value is exceeded
➙ blind extends/lowers after 5 seconds.
➙ orange LED flashes
Light value falls below the specified threshold
➙ upward travel of the awning/blind after 15 seconds.
➙ orange LED stops flashing
You can repeat the operation as often as you want within 5 min-
utes.
In normal operation the orange LED flashes every 5 seconds and
shows that the threshold values have been reached or exceeded.
Checking the wind function (test mode)
Condition:
The blind is retracted.
You can then test the travel movement of your system when the
threshold is exceeded or falls below the threshold specified.
The wind threshold value is automatically set to the lowest value
during the test phase and is reset once the test phase (5 minutes)
is over.
1. Press the UP button (wind symbol) for at least 3 seconds until
the transmission LED flashes.
The test mode stays active for 5 minutes but the LED goes out.
Risk of injury by the upward and downward travel
of the awning.
The test mode is active for 5 minutes. This time
cannot be shortened.
Warning
Keep away from the operating range of the system.
2. Use the hand-held or wall transmitter to move the blind to an
intermediate position.
3. Turn the wind vane. The blind travels in/up immediately. The wind
threshold value for wind is exceeded ➙ red LED flashes.
You can repeat the operation as often as you want within 5 minutes.
The wind alarm lock-out is not active in the test mode.
Note:
In normal operation the red LED flashes every 5 sec-
onds and shows that the treshold values have been
reached or exceeded.
Deleting the programmed BiSens SW-Solar
The wind multi-way switch must not be switched to "Function".
1.
Press the UP
and DOWN
buttons at the
same time.
The BiSens SW-Solar is deleted from the receiver.

Mounting options

Risk of injury by the upward and downward travel
of the awning.
Downwinds on the façade can lead to destruction of
the equipment.
Warning!
The BiSens SW-Solar cannot detect these.
Please pay attention to this advice when choosing
your mounting position.
Note:
Before mounting in the intended mounting position,
check that the BiSens SW-Solar and the receiver work
correctly. The BiSens SW-Solar must not be mounted
under projecting structures.
Wall bracket
The BiSens SW-Solar can be fastened to the upper side of the roof
or to the façade using the hinged wall bracket.
The wall bracket can be swivelled between -5° and 180°. Secure
the required position once it has been set (see screw a).
a
Wall bracket
hinged at 180°