TROUBLE SHOOTING GUIDE
The following guide provides information on how to identify and correct troubleshoot reactions.
E01
Battery over-voltage protection
E02
Battery low-voltage protection
E03
Battery failure
E04
Battery discharge over-temperature protection
E05
Battery discharge low-voltage protection
E06
Battery charge over-temperature protection
E07
Battery charge low-temperature protection
E08
1
Group battery low-voltage protection
st
E09
2
Group battery low-voltage protection
nd
E10
3
Group battery low-voltage protection
rd
E11
4
Group battery low-voltage protection
th
E12
Inverter bus cable voltage failure
E13
Inverter over-load protection
E14
Inverter short-circuit
E15
Inverter cooling fin discharge over-temperature
protection
E16
Inverter cooling fin temperature detector is fall off
E17
PV Input over-voltage protection
E18
PV output over-voltage protection
E19
PV cooling fin charge over temperature protection
over-temperature protection
E20
PV cooling fin temperature detector felt off
E21
Battery protection board charge protection
E22
Battery false detection
E23
Generator over-load (AC&DC) protection
If you are still experiencing trouble with your Jauch Power Bank, please call our Customer Service
at +(1) 360 633 7200 or (+49) 07720 945 314 or by email at energysolutions@jauch.com.
Only discharge possible; no charging
Charge the power station and restart it after fully
charged.
Charge the power station and restart it after fully
charged.
The unit is too hot. Cool down the power station
before charging the power station.
The temperature of the battery is too low. Restore
the battery by increasing its temperature.
The unit is too hot. Cool down the power station
before charging the power station.
The temperature of the battery is too low. Restore
the battery by increasing its temperature.
Charge the power station and restart it after fully
charged.
Charge the power station and restart it after fully
charged.
Charge the power station and restart it after fully
charged.
Charge the power station and restart it after fully
charged.
Please restart the power station.
Please reduce the load and restart the power
station.
Correct the short-circuit output and restart the AC
Output.
Cool down the power station.
Connect the NTC and restart the power station.
Please check if you have used the PV input solar
panel in a proper way. If so, disconnect the PV,
restart the power station and connect the PV again.
Please check if you have used the PV input solar
panel in a proper way. If so, disconnect the PV,
restart the power station and connect the PV again.
Recharge after the temperature of the cooling fin is
lower.
Please contact our Customer Service.
Recharge after the temperature of the protection
board is lower.
Disconnect the PV and restart the power station.
Reduce the total load and restart.