Instructions
CAUTION: Prior to using this device, read
these instructions and keep them in a safe
place for future reference. Rx only. This
device is designed for external examina-
tion only within professional healthcare
facilities by medical professionals.
CAUTION: Do not use the device in fire
or explosive risk area (e.g. oxygen-rich
environment).
CAUTION: This product contains glass.
Dropping or mishandling device may cause
glass breakage. Be careful when handling
broken glass; glass may be very sharp.
WARNING: This product can expose you to
chemicals including methylene chloride
and hexavalent chromium, which are
known to the State of California to cause
cancer or reproductive toxicity. For more
information go to www.P65Warnings.
ca.gov.
EMI Compatibility
This Product conforms to the electromag-
net emissions standard IEC 60601-1-2:
2014.
The EMISSIONS characteristics of this
equipment make it suitable for use in
industrial areas and hospitals (CISPR
11 class A). If it is used in a residential
environment (for which CISPR 11 class B is
normally required) this equipment might
not offer adequate protection to radio-fre-
quency communication services. The user
might need to take mitigation measures,
such as relocating or re-orienting the
equipment.
Portable and mobile RF communications
equipment can affect medical electrical
equipment.
Use of this equipment adjacent to or
stacked with other equipment should be
avoided because it could result in im-
proper operation. If such use is necessary,
this equipment and the other equipment
should be observed to verify that they are
operating normally.
Use of accessories, transducers and ca-
bles other than those specified or provided
by the manufacturer of this equipment
could result in increased electromagnetic
emissions or decreased electromagnetic
©2019 by 3Gen, Inc. | All rights reserved.
immunity of this equipment and result in
improper operation.
Lumio 2 is an internally powered skin
examination device with broad-spectrum
white light and a range of UV light wave-
lengths designed to view the skin with
magnification and clarity.
Directions for Use
CAUTION:  Do not look directly into the
bright LED light. Patients must close their
eyes during facial examinations.
CAUTION: Check the correct operation
of the device before use! Do not use the
device if there are visible signs of damage
or the lights begin to flash.
IMPORTANT: Before initial use, please
charge the internal lithium ion battery.
See "Battery & Charging" for details.
Hold Lumio about 75-150 mm (3-6")
above the skin to be examined. Press the
left button (W) to power on the device in
polarized white light mode. Pressing the
left button (W) again – while the device is
on – toggles between white light and the
most recently-used UV lighting mode. To
choose between UV light wavelengths,
tap the UV button until the UV indica-
tor (UVI) corresponding with the desired
wavelength illuminates. Note that the
"Wood" mode is a blend of UV wave-
lengths that approximates the spectrum
of a classic Wood's lamp.
Choose from one of three brightness
levels by pressing the brightness button
(BR). The selected brightness level cor-
responds with the number of brightness
indicators (BI) illuminated.
Look through the lens with your eye
placed 100-150mm (4-6") above the
device. Move the device closer or farther
away from the skin to obtain the desired
image focus and field of view.
To turn off the unit, push and hold any
button about 1 second. In order to save
power, the device will turn off automati-
cally after 3 minutes.
OptiClip™ Accessory
WARNING: This device contains magnets.
Do not use in proximity of pacemakers or
other magnetically sensitive devices or

Werbung