error / cause / repairing
The pump is very loud and does not bring the normal power.
Wrong motor direction of rotation
The pump is loud and does not take full power.
The engine cover swipes.
The pump is not running or is running difficultly and slowly.
phase is missing.
When turning on, the fuse switches.
incorrect setting
The pump can not be switched from the pool.
The switching tube is kinked or jammed /
too long / Fuses/ power supply/
motor protective button
The switch hose goes off the PN-button.
operating instructions for the end user
Turn on/off the pump:
By pressing the PN-button, the pressure wave switch is actuated and the pump is in opera-
tion. Press again to turn off the pump.
Wintering of the massage system
For a frost-free wintering, the pump and the piping should be emptied completely. The
pump must be emptied with the help of the draining screw on the front.
18
Reverse the polarity of motor by swapping
the phase (400 V).
Fan cover loosely, fix properly.
Change supply line.
Set the correct current value + 10%.
Check whether the pump can be switched
from the control box. / Shorten the hose,
if necessary. / Check the fuses and the
power supply. Test the motor protective
button.
Fix the clamping collet.