Herunterladen Inhalt Inhalt Diese Seite drucken

Quick Start Guide; Wireless Microphone; Safety Instructions - nedis MPWL500BK Kurzanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
a

Quick start guide

Wireless Microphone

For more information see the extended manual
online: ned.is/mpwl500bk
Intended use
The Nedis MPWL500BK is a wireless microphone with a receiver.
This product is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning the use of the product by a person
responsible for their safety.
The product is intended for indoor use only.
The product is not intended for professional use.
Any modification of the product may have consequences for safety,
warranty and proper functioning.
Specifications
Product
Article number
Operating frequency
Maximum transmit power
Signal range (line of sight)
Ideal signal range
Signal type
Channels
Volume level adjustment
Frequency response
Polar pattern
Sensitivity
Impedance
Max. battery play time
(at 50 % volume)
On/off switch
Receiver connection
Power input
Battery
Main parts (image A)
1
Microphone
2
Status indicator LED
3
On / mute / off switch
4
Battery compartment
5
Power adapter
6
6.35 mm audio cable
7
AUX output
8
Channel button (no function)

Safety instructions

-
WARNING
Ensure you have fully read and understood the instructions in
this document before you install or use the product. Keep this
document for future reference.
Only use the product as described in this document.
Do not use the product if a part is damaged or defective. Replace
a damaged or defective product immediately.
Do not drop the product and avoid bumping.
MPWL500BK
Wireless Microphone
MPWL500BK
863.5 MHz
15 dBm
Up to 50 m
Up to 30 m
UHF
1
Yes
40 Hz - 15 KHz
Cardioid
-97 dB
1500 Ω
Up to 5 hours
Yes
6.35 mm output
12 VDC ; 500 mA
2 x 1.5 V AA (not included)
9
Power input
10
Antenna
11
Power button
12
Volume knob
13
Power indicator
14
RF indicator
15
AF indicator
Unplug the product from the power source and other equipment
if problems occur.
Only use the provided power supply.
Do not expose the product to water or moisture.
Do not expose the product to direct sunlight, naked flames or
heat.
Keep distance from flammable objects.
This product may only be serviced by a qualified technician for
maintenance to reduce the risk of electric shock.
Do not dismantle, open or shred secondary cells or batteries.
Do not expose cells or batteries to heat or fire. Avoid storage in
direct sunlight.
Do not short-circuit a cell or a battery.
Do not store cells or batteries haphazardly in a box or drawer
where they may short-circuit each other or be short-circuited by
other metal objects.
Do not subject cells or batteries to mechanical shock.
In the event of a cell leaking, do not allow the liquid to come in
contact with the skin or eyes. If contact has been made, wash the
affected area with copious amounts of water and seek medical
advice.
Always purchase the battery recommended by the product
manufacturer for the product.
Do not remove a cell or battery from its original packaging until
required for use.
Do not use any cell or battery which is not designed for use with
the equipment.
Use only the cell or battery in the application for which it was
intended.
Do not mix cells of different manufacture, capacity, size or type
within a product.
Wipe the cell or battery terminals with a clean dry cloth if they
become dirty.
Battery usage by children should be supervised.
Observe the plus (+) and minus (–) marks on the cell, battery and
equipment and ensure correct use.
When possible, remove the battery from the product when not in
use.
Properly dispose of the empty battery.
Seek medical advice immediately if a cell or a battery has been
swallowed.
Some wireless products may interfere with implantable medical
devices and other medical equipment, such as pacemakers,
cochlear implants and hearing aids. Consult the manufacturer of
your medical equipment for more information.
Inserting the batteries (image B)
Use only size AA batteries for this product.
-
1. Open the battery compartment A
2. Place 2 size AA batteries (not included) into A
Make sure to match the (+) and (-) polarity markings.
-
4
3. Close A
.
Connecting the receiver
1. Plug the power adapter A
2. Plug the other end of A
3. Extend the antenna A
Switch on the receiver
1. Press the power button A
2. The power indicator A
3. Plug the 6.35 mm audio cable A
4. Plug the other end of A
Rotate the volume knob A
sound level.
t
The RF indicator A
switched on.
4
4
.
4
.
5
into the power input A
5
into a power outlet.
q
and point it upwards.
w
to switch on the product.
r
lights up.
6
into the AUX input A
6
into your audio output device.
e
to adjust the volume to the desired
lights up red to indicate the microphone is
9
.
7
.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis