Remarks:
1. Do not operate sprayer without liquid in tank. Sprayer should remain upright at all times.
2. To prime pump, hold wand below level of fluid in tank when switching sprayer on.
3. Nozzle turns to adjust spray from fine mist to a coarse spray or solid stream.
4. Loosen wand nut to adjust length then tighten before use.
5. Do not store sprayer with fluid in tank, and wand spray tip lower than fluid level.
Liquid may be siphoned out of tank.
VI. MAINTENANCE AND STORAGE
Before any intervention on product, ensure that product OFF.
MAINTENANCE
 Clean plastic parts with a soft clean cloth.
Do not use aggressive cleansers (solvents or abrasive cleansers), or an abrasive sponge.
 Do not put or immerse product in water or any other liquid.
 When not spraying, do not place wand tip lower than fluid level in tank. Liquid may be
siphoned out of tank
 Wash tank and tank cap with soapy water
 Put clean water in bottle and spray for about 1 minute to flush out residue from pump and
nozzle
 When sprayer will not be used for a long period of time, remove batteries
 Do not use in rain or pour water on sprayer as it could cause unit to fail
 Before storing, be sure all fluid has been drained from tank and nozzle
 Do not store sprayer where it might freeze. Residual fluid can cause damage and sprayer failure
if fluid freezes

PROBLEM SOLVING

Problem
No Pump Sound
Pump Sounds But Does Not
Spray
STORAGE
Product must be stored in a dry location. Always lock up product and keep out of reach of children
Cause
Dead battery
Improper battery installation
Dead battery
Folded hose or clogged filter
Clogged nozzle
Inside of pump dry
Solution
Install new batteries
Reinstall batteries
Install new batteries
Straighten hose, clean filter
Remove nozzle and clean.
To prime pump, hold wand
below level of fluid in tank
when switching sprayer on