V. Maintain the filter
1. Press the battery locker to disconnect
the Battery from the bin
3. Take out the filter case , then take out
the filter
5. Dry the HEPA filter and filter case
completely before placing them back
7. Put the filter case back to the bin
8
2. Open the bin (shown as below)
4. Wash the filter case and HEPA filter
6. After drying , assemble the filter to
the case
8. Assemble the dust cover into the dust
cup (Shown as below)
Troubleshooting
PROBLEM
LIGHT
POSSIBLE CAUSE
1.The adapter is not inserted into
the wall socket properly.
No light
2.Battery part does not connect
with the bin part
3.The charger is damaged
The appliance is
not charging
After a long time
of charging, the
red light keeps
There should be some problem
flashing for 10
with its internal PCB board
seconds and then
turns off
The main
Red light flashes
1.Low battery
unit does
after you press the
2.The roller brush is blocked by hair
not function
power on button
or something else
properly
The main unit
works normally
Green light lights
1.The rubber belt of the brush bar
but the brush
up as normal
may be loose
bar won't spin
The appliance
has a lower
Green light lights
1.The bin is full
suction power
up as normal
2. Brush's axis is twined by hair
than usual
TECHNICAL SPECIFICATIONS
Battery voltage
22.2V
Charging time
4 hours
Net Weight
2.3kg
Run time
40min (low speed), 25min (high speed)
Power
120W
Vacuum Suction
7kPa
20m 3 /s
Airflow(max)
Battery volume
2200mA
Bin volume
500ml
SOLUTION
1.Make sure that the adapter is inserted
into the wall socket properly.
2.Make sure the battery part slides into
the bin part with a clear "click" sound
3.Change for a new manufacturer
recommended charger
Please contact us for help or take it
repaired by a professional.
1.Fully charge the appliance
2.Remove obstacles from the roller
brush
3.Please contact us for help or take it
repaired by a professional.
Please contact us for help or take it
repaired by a professional.
1. Clean the bin
2. Clean the filter according to
instructions
3. Clean the hair
9