1
signal distortion analysis, fast statistical analysis
2
analysis of temporal EIS/temperature dynamics,
„experiment during measurement" mode, biosensor
applications, 3D time-frequency analysis
3
regression enabled, the highest resolution of
temporal dynamics
4
excitation enabled, analysis of pre-treated fluidic
samples, characterization of non-chemical treatment
5
frequency impedance spectroscopy, differential
analysis of samples, FRA profiles
6
environmental measurements
7
electrophysiological measurements of tissues,
physiological measurements (with corresponding
sensors), differential potential analysis
8
electrochemical interface to bio-samples, biological
tissues and plants
N
Device versions
1
phytosensor basic
phytosensor advanced
2
phytosensor full
3
EIS, open electrodes
4
5
EIS, embedded version
6
biosensor
*transition from phytosensor to EIS/Biosensor requires software activation
All measurements in differential modes (time-differential or channel-differential) do
not require calibration. The calibration can be performed by users for measuring an
absolute value of conductivity at a fixed frequency or for linearizing the frequency
dependent EIS dynamics. The device is CE/FCC/CCC/WEEE certified, certificates
can be found on the device home page or by request: CYBRES GmbH, Melunerstr.
40, 70569 Stuttgart, Germany, info@cybertronica.de.com. Guarantee: 12 months
after selling. Please register per email for obtaining software/hardware updates.
Documentation, user manual, application notes and other materials:
www.cybertronica.de.com/products/MU-EIS-spectrometer
www.cybertronica.de.com/products/phytosensor
www.cybertronica.de.com/products/biosensor
Measurement modes and device versions
Application
1 channel biopotentials & impedance
+ TransAmb sensor (leaf transpiration)
+ 2 channels biopotentials & impedance
+ 2x EIS electrodes, + fluidic/environ. t
Hardware
+ sup flow sensor
sensors, + excitation spectroscopy
different device with thermostat, +
RGB/IR excitation spectroscopy
+ fermentation module,
+ RGB/IR excitation spectroscopy
DDS mode
Configur.
signal scope
continuous
modes
biosensor
continuous
modes
continuous
modes
frequency
modes
off
off
phytosensor
continuous
phytosensor,
modes
biosensor
Software
enabled
enabled
enabled
activation
enabled
enabled
EIS
EIS,
EIS
EIS
EIS
EIS
code*