PART NO.:
GB
C1973: 5 µm filter regulator w. automatic drain
C1971: 5 µm filter regulator w. manual drain
C1970: 5 µm filter regulator w. manual drain (transparent bowl)
TECHNICAL DATA:
Port Sizes: Standard: Gl/4 to ISO 1179
Accepts: ISO 228 (BS 2779) Parallel or ISO 7 (BS 21) taper connectors
Maximum inlet pressure: 17 bar
Maximum outlet pressure: 10 bar
Operating temperature: 20°C* to +65°C
*)Consult our Technical Service for use below +2'C. Ice formation may cause malfunction or da-
mage.
Drain: Auto or manual
Note: The automatic drain operates when a rapid change of flow occurs ( differential pressure ).
MATERIALS OF CONSTRUCTION:
Body. Zinc alloy
Bowl: Zinc alloy
Elastomers: Viton rubber
Elements: Sintered plastic
Materials- used are not hazardous to health when used within specified conditions.
FLOW CHARATERICS (Primary Pressure 10bar)I
SECONDARY
PRESSURE
bar
KITS, REPLACEMENT PARTS:
Service kits: (3,4,5B,5C,6,7,10,11A,26): C1999 (WERTHER part. no.)
Wben ordering spare parts please quote model number and kit or part description.
For further iriformation contact your local WERTHER distributor.