A. Precautions
1. Be sure to connect it to a rated power source.
2. Do not keep it in a hot or humid place. Protect it from direct sunlight or being splashed.
3. Do not handle this studio flash and power cord with wet hands.
4. Never attempt to disassemble this studio flash because of high voltages inside the device. Repair
B. Description of parts
1. Power socket
2. Fuse holder
3. Power and modeling lamp switch
4. Test button
5. Flash and modeling lamp output controller
6. Light sensor
7. Power and ready indicator
8. Sound switch/Triggering method selector
9. Sync cord jack
C. Technical data
Note: The above technical data are measured at 23°C ± 3°C and A.C.220V, 50Hz.
Downloaded from
www.Manualslib.com
should be done by authorized technicians only.
Flash output
Guide number
Recycle time
Modeling lamp
Flash output control
Control precision
Modeling lamp output control
Flash duration(sec.)
Flash triggering method
Color temperature
Power source
Fuse
Dimension
Net weight
manuals search engine
ENGLISH
38(M)/130(Ft)
0.5-5 sec.
Step less 1/8-full
Varies along with output of flash
1/2000-1/500
Manual, slave cell, sync cord
approx.5600K
AC220V 50~60Hz
165 x 70 x 75 mm
Approx.1000g
2
150WS
75W
±1%
5A