Herunterladen Inhalt Inhalt Diese Seite drucken

Description; Catalog Number - Asco SentronicLP 617 Serie Installationshandbuch

Digitaler druckregler
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION
1.

DESCRIPTION

The S
A downstream flow amplifier (pressure booster) converts the control pressure into an output pressure. The output
pressure is measured by a pressure sensor and fed to the integrated digital control circuit. The target value is set
via the electrical plug connection as a standard signal [0 to 10 V, 0(4) to 20 mA or a 2-bit digital signal].
S
entronic
different flow rates, such as air dosing via nozzles or turbine rotation speed control.
Using the available DaS software (Data Acquisition Software), the valve can be adapted to the application if
necessary.
The pressure connections and the air vent connections are designed in the same size, which results in short
response times both for increasing the pressure and for reducing the pressure.
Digital pressure control in a closed circuit: An internal pressure sensor measures the output pressure. The
output pressure is adjusted in real time.
The control parameters can be changed with the additional DaS software. The variability of the parameters
used by the valve is ensured by the DaS software. This flexibility makes it possible to adapt the valve to a very
wide range of applications and to optimize the response time and the precision of the valve and prevent it from
overshooting.
After determining the optimum parameters, these can be saved for personal use in a project file, which can be
sent into our Product Support Department for future series production.

1.1 CATALOG NUMBER

Thread connection
G = ISO 228
8 = NPT
Product Series
617
Revision letter
A = initial release
Size
0 = Flange + pressure hold (DN4))
4 = G1/4 + pressure hold (DN4))
6 = G3/8 + pressure hold (DN8)
8 = G1/2 + pressure hold (DN15)
Setpoint
0 = 0-10V
1 = 0-20mA
2 = 4-20mA
5 = 2 Bit, 4 pressure select
Feedback Type
0 = 0-10V
1 = 0-20mA
2 = 4-20mA
1
) only Digital IN, no Digital OUT
Downloaded from
www.Manualslib.com
LP
valve operates with pulsed pilot valves which change the pressure in a control chamber.
entronic
LP
is particularly suitable for pressure control procedures where a constant pressure is required with
G
1
manuals search engine
617
A
C
S
I
²) no Digital IN possible
O
I
XXX PP
Pressure range
03 = 0...3 bar
06 = 0...6 bar
10 = 0...10bar
Options
A00 = Standard
A07 = Oxygen clean
Input / Display with keys
0 = Standard n.c. + Display
1 = Standard n.c.
2 = Analog IN + Display
3 = Analog IN
8 = Digital IN + Display
9 = Digital IN
Output
0 = n.c.
1 = Digital OUT ² (Standard)
EN
IM50279003-15

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für Asco SentronicLP 617 Serie

Inhaltsverzeichnis