Note: in models of ovens pizza FLAME FLAME 4 and 6, the device break draft (equipped with wind) is already
integrated in the exhaust fumes embedded in the oven. In the model the device FLAME 9 break draft is a
separate accessory that must be arranged in case of installation of the type B11.
The device break draft (equipped with wind), in case of installation B11 is necessary to ensure the functionality
of the device in the presence of airflow obstruction or otherwise through the system / exhaust pipe to the outside.
Schematic example of an installation of the type A1 valid only for the FLAME 4 Model
Schematic example of an installation of the type B11 valid for Models FLAME4 and FLAME 6
In models of ovens pizza FLAME 4 and FLAME 6, the device break draft (equipped with wind) is already
integrated into the flue terminal built-in ovens.
At the exit of the flue terminal to install at least 500 mm of vertical pipe.
The vertical section of pipe can be reduced to installation requirements, it is important not to use 90 ° bends
immediately after the union of the tailpipe which provides a metal tube with a diameter of 150 mm.
NO
Collegamento non conforme
Installation not in accordance
86