Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Error Messages - 3M 700 series Betriebshandbuch

Inhaltsverzeichnis

Werbung

Troubleshooting

Troubleshooting

Error Messages

When the unit's power is ON, messages such as those shown below may be displayed. When any such message
is displayed on the screen, please respond as described below. If the same message is displayed after the
treatment, or if a message other than the following appears, please contact your dealer or service company.
Message
CHANGE THE LAMP AFTER
REPLACING LAMP, RESET THE
LAMP TIMER.(*1)
CHANGE THE LAMP AFTER
REPLACING LAMP, RESET THE
LAMP TIMER.(*1) THE POWER
WILL TURN OFF AFTER ** hr.
(*1)
NO INPUT IS DETECTED ON ***
SYNC IS OUT OF RANGE ON
***FH *****kHz ***FV**Hz
CHECK THE AIR FLOW
NOTE
(*1) • Although this message will automatically disappear after 3 minutes, it will reappear every time the power
is turned ON.
(*2) • Lamps have a finite product life. Lamps are characterized by the fact that, after long hours of usage, a
lamp will no longer light up, or the lamp will break or burst. This unit is equipped with an automatic shut-down
function, such that the power will automatically be turned OFF when lamp usage time has reached 2,000 hours.
Please be aware, however, that among lamp types, there are major differences in product lifetimes; a lamp may
thus fail to light even prior to the functioning of the automatic shut-down function of this unit.
28
28
Description
Lamp usage time is approaching 2000 hours. (*2)Preparation of a
new lamp and an early lamp change is recommended. After you have
changed the lamp, please be sure to reset the lamp timer.
Lamp usage time is approaching 2000 hours. (*2)A lamp change within
** hours is recommended. When lamp usage reaches 2000 hours, the
power will automatically be turned OFF. Please change the lamp by
referring to the "Maintenance" section of this manual. After you have
changed the lamp, please be sure to reset the lamp timer.
There is no input signal. Please confirm the signal input connection, and
the status of the signal source.
The horizontal or vertical wavelength of the inputted signal is outside
of the response parameters of this unit. Please confirm the specs for this
unit or the signal source specs.
The internal portion temperature is rising. Please turn the power OFF,
and allow the unit to cool down at least 20 minutes. After having
confirmed the following items, please turn the power ON again. Please
turn the power ON again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
• Does the peripheral temperature exceed 35˚C?