Herunterladen Diese Seite drucken

axing SPU 996-09 Betriebsanleitung Seite 4

Kaskadenbausteine

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Field of application:
The devices are only suitable for in-house distribution of RF signals! If the
device is used for other purposes, no warranty is given!
With the cascading units 8 SAT IF polarization levels including terrestrial sig-
nals (e.g. FM, DAB+, DVB-T/T2) can be distributed to several SAT receivers.
SPU 996-09 = 6 receivers
SPU 998-09 = 8 receivers
SPU 9912-09 = 12 receivers
SPU 9918-09/-19 = 18 receivers
Equipotential bonding and Mounting:
To avoid dangerous power surges (e.g. risk of fire and danger of life) the
devices must be connected to the equipotential bonding according to EN
60728-11.
 To connect the outer conductor of the coaxial cable to the equipotential
bonding, use e.g. QEW Earthing angles at the inputs and outputs of the
device.
 Use the included mounting screws and the mounting holes of the device
(6).
RF-Installation:
Note: For a cascading system with the cascade units you need a multiswitch
SPU 96-09, 910-09 or 916-09 or a head amplifier SVS 990-09.
 Please note when installing these multiswitches or head amplifier the
appropriate operation instructions.
 Connect the outputs of the multiswitch to the inputs of the cascade unit.
Use F/F Quickfix adapters CFA 4-01 (not included in delivery). Using adap-
ters you can easily plug the devices on each other (see 1 to 3).
 If you use several cascade units, connect the outputs of the first cascade
unit to the inputs of the next cascade unit and so on. Note: According to
the dimensions of your SAT system, you may have to use after some casca-
de units a further multiswitch to amplify the trunk signals (4).
 Terminate the outputs of the last cascade unit with the resistors CFA 11-00
you find in the carton box of the multiswitch (5).
 Connect the subscriber ports on the left and right sides to the antenna so-
ckets. Use highly shielded coaxial cables with F connectors. Suitable cables
and connectors can be found in the current AXING catalogue or at
www.axing.com.
1
2
3
6
4
5

Werbung