INSTALLATION INSTRUCTIONS
The mounting dimensions of the pitot airspeed indicator correspond to the so-called small standard.
The diameter of the hole in the instrument panel is 57 mm, the hole circle diameter on the mounting
flange is 67 mm. M 4 countersunk screws are used for fastening. The instrument panel should be flat
and fixing holes should be accurately located for stress-free mounting of the instrument. The
instrument panel should be well sprung.
The airspeed indicator must be connected to the total pressure (measured pressure) and the static
pressure; static pressure is tapped either from the second connection of the pitot tube or by static
pressure sensors attached to the fuselage sides. The pressure tapping point should be selected so
that no errors are produced from air flow around the aircraft fuselage.
Hose leads should be as short as possible and must not be twisted or contain sharp bends. Kinking of
hoses should be avoided in all cases. Hoses and connections must be absolutely leak-tight. The
instruments must be protected from water penetration. If the hose from the pressure tapping points
cannot be run upwards, a water trap (waterbag) should be fitted at the lowest point.
Before putting into service, a test must be carried out for leak-tightness. If the aircraft manufacturer has
not given any special instructions for this, our standard instruction for leak-thightness testing, January
1978 edition, can be used.
MAINTENANCE INSTRUCTIONS
Leak testing should be carried out at least every 2 years. Otherwise, the instument dose not require any
maintenance.
We recommend that airspeed indicators are subjected to retesting after 5 years.
RETESTING AND REPAIR
The service condition and accuracy of measurement of the altimeter is normally retained over a long
period. For obvious malfunction the unit should be subjected to an investigation at the manufacturer
or a suitable aircraft engineering company. It should be packed to protect it from impacts and
connections should be sealed. Under no circumstances should you interfere with the measuring
mechaism of the airspeed indicator.
ACCOMPANYING DOCUMENTS
New instrument:
1 ) Test certificate EASA Form One, POE
2 ) Installation and maintenance instructions.
Used instrument:
1 ) Test certificate EASA Form One, POE
ATTENTION
This issue replace all previous editions.
Gebr. Winter GmbH & Co. KG
Hauptstraße 25 · D-72417 Jungingen
Telefon +49 (0) 74 77 2 62 + 15 12 63
Telefax +49 (0) 74 77 10 31
e-mail: info@winter-instruments.de
Internet: www.winter-instruments.de
LBA-Anerkennung:
EINBAU- UND WARTUNGSANWEISUNG FÜR DIE STAUDRUCK - FAHRTMESSER
Bezeichnung des Gerätes
Instrument description
Staudruck-Fahrtmesser
Einbaumaße:
Pitot airspeed indicator
Fahrtmesser
Mounting dimension:
Airspeed indicator
7 FMS
Staudruck-Fahrtmesser
Pitot airspeed indicator
Staudruck-Fahrtmesser
Pitot airspeed indicator
* siehe "Sonderausstattung und Festlegung der Sachnummer"
Herstellungsbetrieb gemäß EASA Ref. DE.21G.0115
Instandhaltungsbetrieb gemäß EASA Ref. DE.145.0305
7 FMS 2, 7 FMS 4 und 7 FMS 5
Ausgabe: Januar 2015
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR PITOT
AIRSPEED INDICATORS Types 7 FMS 2, 7 FMS 4 and 7 FMS 5
Issue: January 2015
7 FMS 4
7 FMS 5
Sach-Nr.*
Anzeigebereich
Indication range
part no.*
7211
30 - 200 km/h
7221
30 - 250 km/h
7212
20 - 120 mph
7 FMS 2
7222
20 - 160 mph
7 FMS 2
7213
20 - 100 knots
7223
20 - 140 knots
7511
50 - 300 km/h
7521
50 - 350 km/h
7 FMS 5
7512
30 - 180 mph
7522
30 - 220 mph
7 FMS 5
7513
30 - 160 knots
7523
30 - 200 knots
7411
0 - 250 km/h
7421
0 - 300 km/h
7 FMS 4
7412
0 - 160 mph
7422
0 - 180 mph
7 FMS 4
7413
0 - 140 knots
7423
0 - 160 knots
*see "Special equipment and definition of part number"

Werbung

loading

Inhaltszusammenfassung für Winter 7 FMS serie

  • Seite 1 Gebr. Winter GmbH & Co. KG Hauptstraße 25 · D-72417 Jungingen INSTALLATION INSTRUCTIONS Telefon +49 (0) 74 77 2 62 + 15 12 63 The mounting dimensions of the pitot airspeed indicator correspond to the so-called small standard. Telefax +49 (0) 74 77 10 31 e-mail: info@winter-instruments.de...
  • Seite 2 Fahrtmesser-Skala. In allen anderen Fällen ist die Sachnummer aus den technischen Unterlagen Luftfahrzeughersteller hierfür keine speziellen Anweisungen festgelegt hat, kann unsere des Luftfahrzeug-Herstellers oder durch Rückfrage bei der Firma Gebr. Winter GmbH & Co. KG zu TECHNICAL DATA Standard-Anweisung für die Dichtigkeitsprüfung, Ausgabe Januar 1978, herangezogen werden.

Diese Anleitung auch für:

7 fms 27 fms 47 fms 5