FUNCTION PROGRAMMING (DIP SWITCH - Sw1)
The settings are stored during the rest phase (gate closed).
DIP
Stato
DIP 1
OFF
STEP-BY-STEP
DIP 2
OFF
DIP 1
ON
STEP-BY-STEP
DIP 2
OFF
DIP 1
OFF
CONDOMINIUM
DIP 2
ON
DIP 1
ON
DIP 2
ON
ON
DIP 3
PRE-FLASHING
OFF
ON
DIP 4
SAFETY DEVICE
OFF
ON
PHOTOCELL DURING
DIP 5
OFF
ON
AUTOMATIC
DIP 6
OFF
ON
DIP 7
DECELERATION
OFF
ON
DIP 8
FAST CLOSING
OFF
ON
DIP 9
OFF
LED POWER
ON
DIP 10
OFF
Funzione
Descrizione
I Start pulse:
II Start pulse:
WITH STOP
III Start pulse
IV Start pulse:
I Start pulse:
II Start pulse:
IV Start pulse:
During opening does not receive other Start commands after the first one; during
Pause subsequent Start commands reload the pause time.
I Start pulse: OPEN
Subsequent Start pulses: Uninfluential
Pause from opening limit switch
Start pulse during pause: Reloads the pause time (if DIP 6 ON)
Subsequent Start pulse: OPEN
If Start button is held down:
DEAD MAN
If Pedestrian button is held down:
In this function safety devices and decelerations are not active.
Enables pre-flashing of 2 seconds before motor activation during opening and closing.
Disables pre-flashing.
Enables the safety device TEST before activating the opening and closing cycle.
The test consists of temporarily cutting the power to the devices and checking proper
switching of the contact.
The cycle can only start if the devices work perfectly, if not, three prolonged flashes
indicate the fault.
TEST
Disables the safety device test.
When the photocell is intercepted during both opening and closing, the gate motion is
locked until the photocell is freed. Subsequently, there is always an opening phase.
OPENING
Disables the photocell function during opening.
Enables automatic closing after the pause time adjustable with the trimmer TR5
PAUSE between 2 and 215 seconds.
CLOSING
Disables automatic closing.
Enables deceleration during both opening and closing when the respective limit
switch is intercepted. The deceleration speed is adjusted with the trimmer TR3
SLOW. This function provides for use of 4 magnets (see drawing 2).
Disables the deceleration function. Only 2 magnets are required (see drawing 2).
Reduces the pause time to 3 seconds after intervention of one of the photocells.
Disables the fast closing function.
Not used.
Not used.
Supplies the LEDs (which will come on depending on the respective contact).
After proper installation, the LED power supply can be deactivated to save energy.
SUPPLY
Disables the warning LED power supply.
OPEN
STOP (will not reclose automatically)
:
CLOSE
OPEN
OPEN
CLOSE
OPEN
or CLOSES (if DIP 6 OFF)