Herunterladen Diese Seite drucken

axing premium-line SVS 550-09 Betriebsanleitung Seite 4

Vorschau ausblenden Andere Handbücher für premium-line SVS 550-09:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Field of application:
The devices are only suitable for in-house distribution of RF signals! If the
device is used for other purposes, no warranty is given!
1
1
1
Equipotential bonding and Mounting:
To avoid dangerous power surges (e.g. risk of fire and danger of life) the
devices must be connected to the equipotential bonding according to
EN 60728-11.
 Use the equipotential bonding connection at the device (1).
 To connect the outer conductor of the coaxial cable to the equipotential
bonding, use e.g. QEW Earthing angles at the inputs and outputs of the
device.
 Mount the device on a flat surface. Use the included mounting screws
and the mounting holes of the device (2).
Level Adjustment:
The terrestrial input and all SAT input levels can be adjusted (3).
2
3
RF Installation:
 Connect the SAT inputs of the head
amplifier to the LNBs of your SAT
reception antenna. Connect the out-
put signals of a terrestrial amplifier
or a CATV amplifier to the terrestrial
input.
Use highly shielded coaxial ca-
bles with F connectors. Suited
cables and plugs can be found at
www.axing.com.
 Connect the outputs with the inputs
of a multiswitch. Connect them with
F/F Quickfix adapters CFA 4-01.

Werbung

loading

Diese Anleitung auch für:

Premium-line svs 990-09Premium-line svs 1717-09