Herunterladen Diese Seite drucken

axing premium-line SVS 550-09 Betriebsanleitung Seite 3

Vorschau ausblenden Andere Handbücher für premium-line SVS 550-09:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety advices:
 Installation and repairs to the equipment may only be carried out by
technicians observing the current VDE guidelines. No liability will be
assumed in the case of faulty installation and commissioning.
 Before handling the device, pull out the mains plug, otherwise there is
danger to life. This also applies if you clean the device or work on the
connections.
 Only use the mains cable connected to the device. Never replace any
parts or make any modifications on the mains cable. Otherwise there is a
risk of mortal injury for which we cannot be held liable.
 If a replaceable fuse is available, pull the mains plug before changing
the fuse. Replace damaged fuses only with standard fuses of the same
nominal value.
 The equipment may only be operated in dry rooms. In humid rooms or
outdoors there is danger of short-circuit (caution: risk of fire) or electro-
cution.
 The mains plug is used as a disconnecting device from the mains voltage
both during service and in case of danger and must therefore be reacha-
ble and usable at all times. After connection to the mains, the device is in
operation.
 To prevent damage to your equipment and to avoid possible peripheral
damages, the devices foreseen for wall mounting may only be installed
on a flat surface.
 Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections.
 The location of installation or mounting must allow a safe installation of
all cables connected. The mains cable as well as feeder lines may not be
damaged or clamped by objects of any kind.
 Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
 Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
 Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.).
 Devices that are equipped with heat sinks or ventilation slots must under
no circum-stances be covered or blocked. Also ensure for a generous air
circulation around the equipment. In this way you avoid possible damage
to the equipment as well as a risk of fire caused by overheating.
 In case of damage, interrupt the power supply immediately.
 Do not try to repair the device. This device should only be serviced or
repaired by qualified service personnel. Contact your distributor for more
information.
 Do not open the device.
 For disassembly always pull the mains plug first and disconnect the
power supply cable from the connected device.
State of the art 2020-04-07
Technical improvements, changes in design, printing- and other errors expected.
Technical data:
Type
SVS 550-09
Inputs
Number
5
Frequency range
5...65 MHz | 85...862 MHz | 950...2200 MHz
Attenuator adjustment range
Gain TERR
Gain SAT
Isolation SAT inputs | SAT inputs
Isolation TERR | SAT
Gain return path (passive)
Trunk outputs
Number
5
Max. output level TERR (3rd or-
der EN 50083-3, 60 dB KMA)
Max. output level trunk SAT (3rd or-
der EN 50083-3, 35 dB KMA, 2 sen-
der test method)
Isolation TERR | SAT
Isolation SAT | SAT
Connectors
Connector type
General
Switching power supply
90...250 V~ | 47...63 Hz
18 V=0,7 A
Power consumption
10 W
Equipotential bonding connection
4 mm²
Operating temperature range
(acc. to EN 60065)
195 × 145 × 85
Dimensions (W × H × D) appr.
mm
Protection class
CE Confirmation Declaration
Hereby, AXING AG declares that the device is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet
address: https://axing.com/en/downloads/ce/.
WEEE Nr. DE26869279 | Electrical and electronic components must not be disposed of
as residual waste, it must be disposed of separately.
Manufacturer
EEA contact address
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
SVS 990-09
SVS 1717-09
9
17
0...15 dB
15 dB
21...27 dB
SVS 550-09 | SVS 990-09
40 dB
40 dB
-2 dB
SVS 1717-09
9
17
109 dBµV
premium-line
114 dBµV
Head amplifiers
40 dB
40 dB
Operation instructions
F
18 V=/1,2 A
18 V=/2 A
14 W
22 W
-
4 mm²
-20...+50°C
255 × 145 × 85
430 × 145 × 85
mm
mm
IP 20

Werbung

loading

Diese Anleitung auch für:

Premium-line svs 990-09Premium-line svs 1717-09