Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Of The Clima Eco Minimum Fan Speed; Operation Of The Clima Eco Minimum Fan Speed; Connecting Sensor; Control And Set The Clima Eco Minimum Fan Speed - TechGrow Eco serie Handbuch

Minimale lüfterdrehzahl
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

1. Installation of the Clima Eco

Minimum Fan Speed

1. Do not place the sensor to be connected in direct
sunlight nor in the direct airflow of fans, as this may
influence the measurements. The sensor must be
mounted at a height of +/- 1 meter above the floor.
2. Mount the TechGrow Clima Eco Minimum Fan
Speed on the wall with the supplied mounting kit.
3. Connect the sensor to the bottom of the Clima Eco
Minimum Fan Speed.
4. Put the plug of the fan into the outlet of the Clima
Eco Minimum Fan Speed.
5. Put the plug of the Clima Eco Minimum Fan Speed
into an electrical outlet.
6. Ready!
2. Operation of the Clima Eco
Minimum Fan Speed
The Clima Eco Minimum Fan Speed controls the
minimum fan speed to reach or keep the desired room

temperature.

The Clima Eco Minimum Fan Speed has 2 rotary knobs
to set the minimum fan speed and desired temperature
level. Hysteresis: 2 °C. Maximum fan speed: 100%
The fan control works on the basis of the set minimum
fan speed, maximum fan speed (100%), temperature and
hysteresis (-/+ 2°C).
Example
If the desired temperature is set to 27 °C and the
hysteresis is set to 2 °C, the temperature can be between
25 °C and 29 °C (27 °C - 2 °C / 27 °C + 2 °C).
If the temperature is below the set temperature minus
hysteresis (in this example, below 25 °C), the fan runs at
the set minimum fan speed.
If the temperature is above the set temperature plus
hysteresis (in this example, above 29 °C), the fan runs at

maximum fan speed.

If the measured temperature is equal to the set
temperature (in this case 27 °C), the fan runs at idle
speed (see section 4.5).
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
Within the set hysteresis range (+/- 2 °C), the speed is
automatically reduced to the set minimum fan speed or
increased to the maximum fan speed.
NOTE If no sensor is connected to the Clima Eco
Minimum Fan Speed, the fan runs continuously at
the set minimum speed.

3. Connecting sensor

The minimum sensor required is the TempProbe.
Always switch the controller off if you want to replace
the sensor.
4. Control and set the Clima Eco
Minimum Fan Speed
4.1 Minimum fan speed
After installing the Clima Eco Minimum Fan Speed the
fan starts to run (the fan must be on). Set the desired
minimum fan speed "Min Fan Speed" (10% – 100%) by
turning the left knob.
4.2 Maximum fan speed
The maximum fan speed is 100%.
4.3 Temperature
Turn the right knob to set the desired room temperature
"Temp" (15 °C – 35 °C).

4.4 Hysteresis

The hysteresis is 2 °C.

4.5 Idle speed

If the measured temperature in the room is equal to the
set temperature, the fan runs at idle speed. This fan
speed lies in the exact middle of the set minimum fan
speed and the maximum fan speed (100%). If the
temperature deviates within the range of the set
hysteresis, the fan speed will adjust in proportion to the
idle speed.