2. INSTALLATION

2.1 Installation
Before the installation take away the equipment from its packing. Some pieces are protected with a plastic film that
must be taken away with care. If some residuals of glue remains on the surfaces take care to remove it acting with
right substances, like gasoline, and never with abrasive substances.
Fit up the feet on the equipment. The equipment must be leveled (the feets are adjustable for height). Make sure of
the backing plate solidity.
The master switch or the socket must be near the equipment and within easy reach. The installation of an exauste
hood over the equipment is advisable. Take care to observe all fire-fighting law prescriptions.

2.2 Law prescriptions regulations - instructions

The installation must be executed complying the following rules:
-
Accident preventions rules in force.
-
Prescription VDE in force.
2.3 Installation
Installation, start-up and maintenance of the appliance must be performed by qualified staff. All work required for
installation must be performed in accordance with the laws in force. The manufacturer declines all responsibility in the
event of malfunctioning due to incorrect or non-conforming installation.
CAUTION! As per international regulations, during connection of the appliance a device is to be provided upstream of
the same in order to disconnect the appliance, on an omnipolar basis, from the mains. This device must have an
opening of the contacts of at least 3 mm.

2.4 Electrical connection

The connection cable chosen must have the following features: it must be at least H05 RN F and with an adequate
section for the appliance. The junction-boxes are located on the right the equipments. Pass over the cable and
connect the electrical conductors in the corresponding terminal and fix. The earthed neutral must be longer than the
others so in case of breakage of the cable fastener it will come off after the electrical conductors.
2.4 Equipotential
The appliance is to be connected in an equipotential system.
CAUTION! The manufacturer is not responsible, and does not
compensate under guarantee, damage caused by inadequate
installations not conforming to the instructions.