The air is purified with a 3-in-1 filter, consisting of pre-filter, HEPA filter and carbon filter. Each
layer is responsible for eliminating different type of pollution.
Pre-filter: Captures big particles such as dust and hair
HEPA 11: Eliminates 99.5% of 0,3 μm particles such as dust, smoke, pollen and other allergens
Carbon filter: Removes odors and bad smells
1. Prior to first use, take out the filter and remove the protective plastic bag then replace the
filter (see "Filter replacement" section).
2. Place the device on a flat and stable surface. Make sure there is enough space around the
device to allow free circulation (at least one meter from walls or furniture) and that air
inlet and outlet are not blocked.
3. Connect the device to power mains.
4. Press the power button
Note: Press and hold the power button for about 5 seconds to reset the filter replacement
indicator.
5. Keep pressing the timer button
timers: 2 hours, 4 hours and 8 hours. LED light indicates selected timer. When set time is
up, the device will switch off automatically. If timer function is not enabled, the device
will keep operating until manual switch-off.
6. Keep pressing the mode button
modes: night, low, medium, turbo. LED light indicates selected mode.
Notes:
• Default operation mode is medium.
• Turbo mode is on when all three indicators are on.
EN
• In the night mode, all indicators on the control panel are off.
7. Turn off the device by pressing the power button and disconnect it from power supply
(ON/OFF indicator goes off ).
It is time to replace the filter when the filter replacement indicator lights up red. Filters should
be replaced at least once each 6 months. More frequent cleaning and replacing may be
required depending on environmental conditions.
1. Turn the device upside down.
2. Remove the screw from the base.
3. Take off the base.
3-STAGE FILTRATION SYSTEM

OPERATION

to turn on the device (ON/OFF indicator lights up).
to change timer intervals. There are three available
to change operation mode. There are four available

FILTER REPLACEMENT