3

Assembly and electrical connection

Cut the power supply to the boiler.
Cut the gas supply to the boiler.
Remove the connecting pipe.
Loosen the nuts.
Fit the safety valve using the 3 gaskets provided.
Tighten the connections.
Remove the bridge plug.
Control panel with CCE 9-pin connector:
Connect the connector of the kit to the control panel.
Control panel with CCE 12-pin connector:
Connect the connector of the kit with the adaptor cable to the
control panel.
Remove the bridge plug.
Connect connector to the control panel.
Check the leak tightness of the connections (A - B - C).
6
3

Montage en elektrische aansluiting

E
Haal de stekker van de verwarmingsketel uit het
stopcontact.
Onderbreek de gasvoeding van de ketel.
Demonteer de verbindingsbuis.
Draai de moeren los.
Monteer de veiligheidsklep met de 3 meegeleverde pakkingen.
Draai de verbindingen vast.
Verwijder de contrapen met de bruggen.
Bedieningspaneel met connecteur CCE 9 contactpunten:
Sluit de connector van de set aan op het bedieningspaneel.
Bedieningspaneel met connecteur CCE 12 contactpunten:
Sluit de connector van de set met de aanpaskabel aan op het
bedieningspaneel.
Verwijder de contrapen met de bruggen.
Sluit de connector aan op het bedieningspaneel.
Controleer de dichtheid van de aansluitingen (A - B - C).