[B000170] 14. THE RANGE OF ENVIRONMENTAL CONDITIONS, FOR
WHICH THE DOOR HAS BEEN DESIGNED
• Temperature
• Relative humidity
• Electromagnetic fields
Refers to manually operated doors. The range of environmental conditions for
the doors with drive is stated in the Assembly and Operating Instruction of the
drive.
[C000050] 15. ROUTINE MAINTENANCE INSTRUCTION
Activities, which may be performed by the Owner after careful
reading of the Instruction supplied with the door:
[A000060] Disconnect the drive power supply during
all maintenance and inspection works.
[C000413] Clean the outer door leaf surface with with a sponge and clean
water or commercially available agents suitable for cleaning of paint coats.
Do not use any abrasive cleaning agents, sharp tools, cleaners based on NC
solvents, or detergents.
Do the ongoing inspection of the door at least every 6 months and:
• Relubricate the hinges, running rollers, springs and tracks with e.g. Wurth
HWS-100 semiliquid grease before commissioning and during operation
of the door.
• Do not grease/lubricate the lock cylinder. Use a graphite grease if neces-
sary.
• During the inspection check the door fasteners on the wall, all bolts/screws
and guide rollers; immediately remove all problems found before using the
door.
• If any operating malfunctions or damage to the door components is found,
stop using the product and contact the Authorised Service.
• Check the drive fastening.
• Check the correct winding and tension of the cables.
[D000231] Clean the stainless steel decoration elements, e.g. with Wurth
cleaning agent for stainless steel, at least two times per month (avoid contact
of the clearing agent with the door leaf).
[C000017] Activities, which may be performed by a Competent
Person having correspondent permissions.
[C000060] The door maintenance should be performed at least once for
12 months. The following activities to be performed during the door routine
maintenance:
• Check spring tension - for this purpose, open the door leaf by lifting the leaf
to half-open position:
• if the leaf is visibly falling, increase the spring tension by its regulation,
• if the leaf is visibly lifting, decrease the spring tension by its regulation.
• The spring tightening procedure is described in the As-
sembly Recommendations.
• If the above mentioned works are not performed,
there is a risk that the leaf may suddenly drop and
hurt people, or cause damage to objects in its vicinity.
• Check the correct and smooth rotation of rollers during door opening and
closing. If the rollers put resistance or do not rotate at all, check their condi-
tion and rolling surfaces in particular. If necessary, replace entire assem-
blies.
• Check the mechanical components ensuring safety and correct door opera-
tion. In case of any failures, these must be immediately eliminated, and faulty
components and parts should be repaired or replaced.
• When mounting a drive, block the door bolts in its open position, or install
additional devices for automatic bolting.
• Check the condition of suspension cables and springs.
[C000261] Activities, which should be performed by a Profession-
al Installer:
Any alterations and modifications to the door should be agreed on with the
door manufacturer.
The range of works covered by the door periodical inspection provided by an
authorised service centre of the manufacturer.
• Identify the door type and serial number.
• Check the door marking, warning labels. Add new ones, if missing.
• Check the connection parts used in the door: door-to-wall mounting anchors,
guide mounting bolts.
• Check the springs and elements working with them. In case of evident wear
and tear signs, the elements should be absolutely replaced.
• When the door has been used for longer than 12 years, or if the door have
made more than 20 000 cycles (the number of cycles should be estimated
Technical description
IIiO/BS/SNP/01/2020/ID-95695
Assembly and Operating Instructions – Sectional garage door UniPro SNP
- –30° C to +50° C
- max. 80% not condesated
- not applicable
on the basis of the interview with the door owner) - the springs should be
absolutely replaced.
• Pay attention to conditions, in which the door is operated. If the conditions are
different from the required operation conditions, the owner should be informed
about possible consequences (e.g. about failure occurrence possibility).
[C000045] 16. RESTRAINTS IN DOOR OPERATION
The door is not intended to be used:
• in an explosive environment,
• as a fire-proof partition,
• in moist rooms,
• in rooms with chemical substances harmful to the protective and paint coatings,
• from the sunny side in case of dark-coloured door leaves,
• as a bearing structure of a building,
• as a hermetic barrier.
[A000011] All works must be performed according to this Assembly and Op-
erating Instruction of the door. Any comments or recommendations must be
submitted to the Owner in writing, e.g. to be noted in the door report book or
warranty card, and submitted to the door Owner. Upon performing the inspec-
tion, this fact must be confirmed by corresponding note in the door report book
or warranty card.
[A000079] The manufacturer reserves the right to introduce design
modifications due to technological progress that do not alter the
product functionality, without prior notice.
This documentation is copyright of the manufacturer. Copying,
reproduction and usage in full or in a part without the written
consent of the owner is prohibited.
[A000048] This document has been translated from Polish. In case
of discrepancies, the Polish version prevails.
EN
5

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis