In the next table you can find out what kind of flash sequence belongs to which error.
Red LED conditions :
 = LED flashing
 = LED ON
 = LED OFF
Time period (1 second)




  Power ON, inverter in normal operation
  Inverter OFF
3.2

Acoustical messages (except PS200-xx models)

To warn you before the inverter might shut down, the inverter is equipped with an
acoustical alarm. There are three kinds of acoustical messages depending on the cause of
possible inverter shutdown. These messages are related to the red LED blinking
sequences mentioned previously.
Message 1: One beep per second. The battery voltage has reached a too low or too
high level. If the battery voltage respectively decreases or increases any
further, the inverter shuts down.
Message 2: Two beeps per second. The inverter will shut down soon due to an
overloaded output. Note that at heavy overloads the alarm will not sound
due to too fast inverter shut down.
Message 3: Three beeps per second. The i e te
temperature is rising another three degrees Celsius.
3.3

Troubleshooting guideline

PROBLEM : Inverter is not working (red LED OFF)
Possible cause :
Power switch in OFF (0) position
Type of error
Battery voltage too low, too high (one flash
per second)
Overloaded or shorted output
(two flashes per second)
Inverter temperature too high. Cooling down
(three flashes per second)
Inverter in ASB mode
(four flashes per second)
ill shut do
Remedy :
Push the power switch in the ON (1)
12
he it s