Seite 1
DPM 959 3½ Digit LED Module Module Miniature LED 3½ Caractères 3½-stelliges LED-Modul Modulo con display LED a 3,5 cifre LASCAR ELECTRONICS LIMITED, LASCAR ELECTRONICS, INC. MODULE HOUSE, PO BOX 8204, WHITEPARISH, SALISBURY, SAVANNAH, GA 31412 WILTSHIRE SP5 2SJ UK...
Seite 2
A compact meter ideally suited to applications where excellent readability under all lighting conditions is required. The meter is fitted with high efficiency LEDs which, together with the integral red filter, give a high contrast display. The meter can be easily scaled by the user to indicate volts, amps or other engineering units and may be used in single-ended, differential, ratio- metric or floating input modes.
Seite 3
Le DPM 959 est un voltmètre compact qui convient parfaitement aux applications qui requièrent une excellente lisibilité quelles que soient les conditions d’éclairage. Il est doté de diodes puissantes placées derrière un filtre rouge qui assurent un affichage d’un très bon contraste. Il peut être facilement configuré...
Ein kompaktes Meßgerät für alle Anwendungen, bei denen gute Lesbarkeit bei allen Beleuchtungsbedingungen erforderlich ist. Das Gerät enthält hocheffiziente LEDs, die, zusammen mit dem eingebauten Rotfilter, eine Anzeige mit hohem Kontrast bieten. Benutzer können das Meßgerät ohne weiteres zum Anzeigen von Spannung, Ampere-Wert oder anderen technischen Einheiten skalieren.
Seite 5
Misuratore compatto particolarmente indicato per le applicazioni in cui è necessaria un'ottima leggibilità in qualsiasi condizione di illuminazione. Il misuratore è dotato di LED ad alto rendimento che, unitamente al filtro rosso integrato, formano un display ad elevato contrasto. Il modulo può...
Seite 6
Specification Min. Typ. Max. Unit SCALING Required F.S.R. Accuracy (overall error) * 0.05 %(±1 count) Linearity ±1 count 2V * 910k 100k Sample rate samples/sec 20V * Operating temperature range °C 200V * Temperature stability ppm/°C 2kV * 100R Supply voltage (V+ to V-) µ...
Seite 7
INPUT VOLTAGE IN HI VOLTAGE IN HI D’ALIMENTATION 100k IN LO EINGANGSSPANNUNG IN LO Zero TENSIONE D'INGRESSO Check Link 2 is OPEN. Measuring 4-20mA to read 0-999. (supply MUST be isolated). Operation with input referenced to panel meter supply (Single ended mode). Preferably link IN LO to V- at signal source (to reduce loop noise), otherwise make Mesure de 4-20mA pour lire 0-999.
Seite 8
Ansicht von hinten VISTA POSTERIORE Specifications liable to change without prior warning DPM 959 Issue 5 January/2000 M.C. Applies to DPM 959/4 Spécifications peuvent changer sans préavis DPM 959 Edition 5 janvier/2000 M.C. Applique à DPM 959/4 Die technischen Daten können ohne vorherige Ankündigung geändert werden...