Herunterladen Inhalt Inhalt Diese Seite drucken

Datalogic S5N-M Serie Bedienungsanleitung Seite 8

Vorschau ausblenden Andere Handbücher für S5N-M Serie:
Inhaltsverzeichnis

Werbung

Standard Command
Index (dec) Command Name
Lenght
0x0002 (2)
SP1 Single Value Teach
1 octet
0x0002 (2)
SP1 Teach TP1
1 octet
0x0002 (2)
SP1 Teach TP2
1 octet
0x0002 (2)
Teach FINE
1 octet
0x0002 (2)
Teach CANCEL
1 octet
0x0002 (2)
Restore Factory Settings
1 octet
0x0002 (2)
Confirm Maintenance
1 octet
0x0002 (2)
Disable IO-Link adjustment
1 octet
0x0002 (2)
Start / Stop Ping
1 octet
Events
Event code (dec)
Event name
0x4220 (16928)
Temperature underrun
0x4210 (16912)
Temperature overrun
0x5100 (20736)
General power supply fault
0x7710 (30480)
Short circuit - Check installation
0x8C40 (35904)
Maintenance required - Lens cleaning
0x8CA0 (36000)
Laser fault
PROCESS DATA
Process Data Output
7
6
Process Data Input
23
22
21
PDV1 (Normalized distance (M03)
15
14
13
PDV1 (Normalized distance (M03)
7
6
Not used
Process data will not be valid in case of out-of-range values.
(2)
Value (dec)
Description
Acquisition EASY (refer to User's Manual) (M03, W03) / Teach Set Point (B01, C01, T01)
0x41 (65)
0x43 (67)
Acquisition FINE: Mark Detection (refer to User's Manual) (W03)
0x44 (68)
Acquisition FINE: Background Detection (refer to User's Manual) (W03)
0x4B (75)
Acquisition FINE (refer to User's Manual) (M03)
0x4F (79)
Exit from teach FAIL status (M03) / Exit from Fine detection (W03)
0x82 (130)
Restore factory settings (Device Access Locks, Application Specific Tag, Function Tag, Location Tag, SSC1 Param, SSC2 Param, Delay Settings, Output Type)
Reset Maintenance parameters (Operating Hours Maintenance, Minimum device temperature since powerup, Maximum device temperature since powerup,
0xA5 (165)
Device Status, Detailed Device Status)
0xAB (171)
Disable teach via IO-Link, re-enable trimmer adjustment (B01, C01, T01)
0xAF (175)
Feature to identify the sensor by yellow led blinking
Event mode
Appears / Disappears
Appears / Disappears
Appears / Disappears
Appears / Disappears
Appears / Disappears
Appears / Disappears
Byte 0
5
4
3
Not used
Byte 2
20
19
/ LIGHT RECEIVED (W03, B01, C01, T01) (MSB))
(2)
Byte 1
12
11
/ LIGHT RECEIVED (W03, B01, C01, T01) (LSB))
(2)
Byte 0
5
4
3
Not used (W03, M03,
T01), Stability (C01)
Alarm (B01)
Event type
Warning
Warning
Error
Error
Notification
Error
2
1
0
TRANSDUCER
DISABLE
18
17
16
10
9
8
2
1
0
TEACH-IN
SSC2 (DO pin)
SSC1 (C/Q pin)
Device status
Remarks
Out of specification
only B01, C01, T01
Out of specification
Failure
Failure
Maintenance required
only B01
Failure
only Laser models
DEVICE VARIANT COLLECTION
Product name
Product ID
Product text
S5N-PA-5-C01-OZ
02210
Diffuse proximity
S5N-MA-5-C01-OZ
22200
Diffuse proximity
Background
S5N-PA-5-M03-OZ
02230
suppression
Background
S5N-MA-5-M03-OZ
22170
suppression
S5N-PA-5-W03-OZ
02240
Mark reader
S5N-PL-5-C01-OZ
02260
Diffuse proximity laser
S5N-ML-5-C01-OZ
22190
Diffuse proximity laser
S5N-PL-5-B01-OZ
02250
Reflex polarized laser
S5N-ML-5-B01-OZ
22180
Reflex polarized laser
S5N-PA-5-B01-OZ
02200
Reflex polarized
S5N-MA-5-B01-OZ
22160
Reflex polarized
S5N-PA-5-T01-OZ
02220
Reflex transparent
Access*
WO
WO
WO
WO
WO
WO
WO
WO
WO
Device ID
2
3
4
5
6
7
8

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

S5n-maS5n-mr

Inhaltsverzeichnis