CONTROLS
OUTPUT LED (S5N-Mx...A00/B01/C01/C10/C21/D00/E01/F01/T01)
The yellow LED ON indicates that the N.O. (normally open) output
status is closed.
STABILITY LED (S5N-Mx...B01/C01/C21/E01/F01)
The green LED ON indicates that the received signal has a reserve
greater than 30% compared to the output switching value.
POWER ON LED (S5N-Mx...G00)
The green LED indicates that the sensor is operating.
TRIMMER (S5N-Mx...B01/C01/C21/E01/F01/T01)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through
a  18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum
tightening torque).
Wide range of accessories available: various orientable fixing brackets
ease the sensor positioning (please refer to the accessories listed in the
general catalogue).
The operating distance is measured from the front surface of the sensor
lens.
C models: To improve the detection, the
object has to be moved closer or further away
from the front surface of the sensor lens.
In case of lateral translation, the object must
move as indicated in the figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
S5N-Mx...G00
BROWN
1
BROWN
1
+
10 ... 30 Vdc
+
WHITE
2
WHITE
2
N.C. OUTPUT
4
BLACK
4
BLACK
N.O. OUTPUT
3
BLUE
3
BLUE
0 V
M12 CONNECTOR
2
1
3
4
AXIAL VERSION
L
14.5
4
4
X
2.5
10
TRIMMER
STABILITY LED
49
OUTPUT LED
FIBRE OPTIC VERSION
12
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulation resistance:
Operating distance (typical values):
10 ... 30 Vdc
TEST +
TEST -
Emission type:
0 V
Ambient light rejection:
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU
DIMENSIONS
RADIAL VERSION
L
12
4
4
X
14.5
M O D E L S
with trimmer
without trimmer
L
67
57
X
43
38
61
72.5
14.5
10
4
6.2
=
50
TRIMMER
STABILITY LED
OUTPUT LED
54.5
TECHNICAL DATA
S5N-MA AXIAL VERSION
10 ... 30 Vdc (limit values)
2 Vpp max.
35 mA max.
N.O. and N.C.; PNP or NPN (short-circuit protection)
100 mA max.
2 V max.
0.5 ms (2 ms mod.F01/G00)
1 kHz (250 Hz mod.F01/G00)
OUTPUT LED (YELLOW) excluding mod.G00
STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01)
POWER ON LED (GREEN) (mod.G00)
sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01)
-25 ... 55 °C
-25 ... 70 °C
500 Vac / 1 min. between electronic parts and housing
>20 M / 500 Vdc, between electronic parts and housing
A00: 0.1...4 M on R2
B01: 0.1...3.5 m on R2
C01: 0...60 cm
C10: 0...10 CM
C21: 0...35 cm
D00: 0.5...10 cm
F01/G00: 0...25 m
E01: 30 mm with OF-42 / 100 mm with OF-43
T01: 0.1...1 m on R2
red (630 nm) (mod. D00/E01) / red (660 nm) (mod.B01/T01)
infrared (880 nm) (mod. A00/C01/C10/C21/G00)
according to EN 60947-5-2
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Nickel-plated brass
PMMA
IP67 Type 1 enclosure
2 m cable  4 mm / M12 - 4 pole connector
110 g. max. cable vers. / 60 g. max. connector vers.
I I 3G EX nA II T6 ;
I I 3D EX tD A22 IP67 T85°C
Setting of S5N-Mx...A00
Position the sensor and reflector on opposite sides.
14.5
Find the points where the yellow LED (OUT) is switched ON and OFF in
both vertical and horizontal positions, and fix the sensor in the center
between these points.
Setting of S5N-Mx...B01/T01
Position the sensor and reflector on opposite sides.
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
middle of the points defined. Optimum operation is obtained when the
10
green LED (mod.B01) is ON and the yellow LED is OFF.
B01 models: If necessary reduce sensitivity in order to detect very small
TRIMMER
targets. In order to improve alignment, repeat the procedure detailed
M O D E L S
above whilst progressively reducing the sensitivity.
with trimmer
without trimmer
T01 model: Turn the sensitivity trimmer counterclockwise
L
79
69
X
43
38
until the yellow LED turns ON (pos.A).
LED STABILITY
LED DI USCITA
Turn slowly the trimmer again clockwise until the yellow
LED turns OFF (Operating condition, pos.B).
mm
Setting of S5N-Mx...F01/G00/E01 with OF-43 (P/R fibre-optics)
Position the sensors (fibre terminals) on opposite sides.
Turn the sensitivity trimmer to maximum: moving the sensor both vertically
CABLE VERSION
and horizontally, determine the power on and off points of the yellow LED
10
(OUT) and then mount the sensor in the middle of the points defined.
Optimum operation is obtained when the green LED is ON and the yellow
LED is OFF (the output function and the relative LEDs are inverted in the
E01 model with the OF-43 fibre).
If necessary, reduce sensitivity using the trimmer, in order to detect very
small targets. In order to improve alignment, repeat the procedure detailed
above whilst progressively reducing the sensitivity.
Setting of S5N-Mx...C01/C21/E01 with OF-42 (proximity fibre)
STABILITY LED
Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow
OUTPUT LED
LED is OFF. Position the target to detect in front of the sensor or of the
fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON (Target detected state, pos.A). Remove the target, the yellow
LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON (Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected.
S5N-MR RADIAL VERSION
Turn the trimmer to the intermediate position C, between the two positions
A and B. The green LED must be ON.
Setting of S5N-Mx...C10/D00
The operating distance range of these sensors is factory preset: please
consider this feature when positioning.
TEST FUNCTION (S5N-Mx...G00)
The TEST+ and TEST- inputs can be used to inhibit the emitter and verify
that the system is correctly operating.
The receiver output should switch when the test is activated while the
beam is uninterrupted.
The inputs activating voltage range is 10 ... 30 Vdc.
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions,
Support.
B01: 0.1...2 m on R2
C01: 0...35 cm
The warranty period for this product is 36 months. See General Terms
C10: 0...8 cm
and Conditions of Sales for further details.
D00: 0...8 cm
F01/G00: 0...20 m
T01: 0.1...1 m on R2
© 2007 - 2019 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS
RESERVED.  Without limiting the rights under copyright, no part of this
documentation may be reproduced, stored in or introduced into a retrieval
system, or transmitted in any form or by any means, or for any purpose,
without the express written permission of Datalogic S.p.A. and/or its
affiliates. Datalogic and the Datalogic logo are registered trademarks of
Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. All
other trademarks and brands are property of their respective owners.
Datalogic reserves the right to make modifications and improvements
without prior notification.
SETTING
A
C
B
MIN
MAX
For information about the disposal of Waste Electrical
and Electronic Equipment (WEEE), please refer to the
website at www.datalogic.com.
821005712 Rev. C

Werbung

loading

Inhaltszusammenfassung für Datalogic S5N-M Serie

  • Seite 1 (630 nm) (mod. D00/E01) / red (660 nm) (mod.B01/T01) BLUE BLUE infrared (880 nm) (mod. A00/C01/C10/C21/G00) © 2007 - 2019 Datalogic S.p.A. and/or its affiliates  ALL RIGHTS Ambient light rejection: according to EN 60947-5-2 RESERVED.  Without limiting the rights under copyright, no part of this 0.5 mm amplitude, 10 …...
  • Seite 2 Tipo di emissione: rossa (630 nm) (mod. D00/E01) / rossa (660 nm) (mod.B01/T01) / NERO NERO © 2007 - 2019 Datalogic S.p.A. e/o le sue consociate  TUTTI I DIRITTI USCITA N.A. TEST - infrarossa (880 nm) (mod. A00/C01/C10/C21/G00) RISERVATI. Senza con ciò limitare i diritti coperti dal copyright, nessuna...
  • Seite 3 ROT, 630 nm (bei Mod. D00/E01) / ROT, 660 nm (bei Mod. B01/T01) N.O. OUTPUT TEST - Sender, Wellenlänge: © 2007 - 2019 Datalogic S.p.A. und/oder die Tochtergesellschaften  ALLE RECHTE INFRAROT, 880 nm (bei Mod. A00/C01/C10/C21/G00) BLAU VORBEHALTEN.  Ohne die im Urheberrecht festgelegten Rechte einzuschränken,...
  • Seite 4 Boîtier: laiton nickelé que ce soit, ni à quelque fin que ce soit, sans l'autorisation écrite expresse de Datalogic Lentilles: PMMA S.p.A. et/ou ses filiales. Datalogic et le logo Datalogic sont des marques de commerce Classe de protection: IP67 Boîtier type 1...

Diese Anleitung auch für:

S5n-maS5n-mr