WS4-4D-E
4 Door access control unit with web access
QUICK USER GUIDE
DESCRIPTION
WS4-4D-E is a 4 door control unit designed to operate with readers with RS485 output.
There is no need to install any software. There is no need to have a dedicated PC
either. Everything is available online and the operators just need to register with
controller's serial number to start using the software application.
SPECIFICATIONS
• Capacity:
2500 Users
• Events:
50000 max.
• Doors:
4 (max. 20 doors in same network)
• Readers:
4
• Door contact inputs:
4
• Push button inputs:
4
• Auxiliary Inputs:
2 (emergency, vehicle detection)
• Auxiliary Outputs:
2 (alarm, storing alarm status, presence)
• Power supply:
120 to 240 V AC, 100 VA-1.52A with fuse (1 A)
• Supply for the readers:
225 mA each max.
• Supply for the locks:
600 mA each max.
• Relay characteristics:
2A/48 VAC/DC#
• Processor:
ARM A5 - 528 Mhz
• Memory:
64 MB Ram DDR2 133 Mhz
• TCP/IP connection:
10/100/1000 Base-T – HTTP or HTTPS
• Housing dimensions:
350 x 250 x 80 mm
• Operating temperature:
0 °C to +50 °C
• Humidity:
0% to 85% (non-condensing)
• Tamper:
Yes
• Wiegand readers connection:
Yes, via Wiegand to RS485 converter - WS4-CNV
• Elevator feature:
Yes, 2 elevators per installation, each - 24 floors
• Interlock, Anti pass back, people counter, presence, system logs, reports in CSV
FIRST CONNECTION AND CONFIGURATION
The WS4-4D-E does not have default IP address. By default is set to DHCP. There are 2
methods to connect to and configure WS4-4D-E - LAN and Standalone method.
METHOD 1
(For use in a home or business LAN network)
In this configuration, the network's DHCP server will assign an IP address to your WS4-4D-E
1. Put the DIP switch 1 in position OFF.
2. Connect a cable from your network to the ethernet connector of WS4-4D-E.
3. Open a web browser and enter http://ws4 followed dash and the serial number of
the WS4-4D-E controller
If you can not connect, it is because your network does not recognize the name of the
EN
FR
IT
ES
DE
NL
WS4-4D-E controller. In this case, go to our web site http://www.xprgroup.com/products/ws4/
and download the tool called "Device Finder".
The "Device Finder" will enable you to find out the IP address of the WS4-4D-E controller.
Run the "Device Finder" and you will get a list of all the WS4 controllers connected in
your network, including their IP addresses, just like the picture below.
Open a browser and type the IP of the WS4-4D-E controller and you will be prompted to the
login page.
User Name: admin
Password: WS4 followed by Dash and the Serial Number (ex. WS4-110034) just like the
image below, all in capital letters without space.
METHOD 2
(For standalone use - without LAN network)
In this configuration, the WS4-4D-E will assign an IP address to your PC. The PC must be set to obtain IP
address automatically.
1. Put the DIP switch 1 in position ON.
2. Connect a cable from your PC directly to the ethernet connector of WS4-4D-E.
3. Open a web browser and enter the following IP - 192.168.50.100, then put the login
credentials like explained above
FACTORY RESET
DIP Switch 4 allows a complete re-initialization of the system. To
do this, switch this dip switch 3 times OFF - ON - OFF within 10
seconds.
CHANGE PASSWORD
DIP Switch 4 allows to log into the system as an administrator if
login or password is forgotten. Toggle this dip switch ON for
about 15 seconds, then back to OFF. The system will then allow,
for 5 minutes, to connect (from the local network only) with the
default login and password.
SOFTWARE SETTINGS
ADDING READERS
Go to "Doors", select the reader(fig.2) and then select the type of the reader in the
field "Card". (fig.3). While off line, red LED blinks fast and buzzer beeps continuously.
Once communication is established, the red LED and the buzzer stop. Green LED
starts to blink continuously. If you want to stop the green LED, go to Settings/System
Options and select for the backlight ON or OFF (not default) fig.4
www.xprgroup.com
fig.1
fig.3
fig.5
To add 2 readers on 1 Door, select the reader (fig.2) and there, for "Type of Access"
select "Access with 2 readers" (fig 5). Fill the form for both readers and they will
merge in one door (fig. 6)
ADDING USERS
Go to Users (fig.1), select "New"(fig.2) and then fill the form (Name, category, card
number...)(fig.3).
fig.1
fig.2
ADDING SLAVE CONTROLLERS
WS4-4D-E system can manage up to 10 WS4-4D boards in the same installation (with up to 20
doors, whether single or double). One WS4-4D-E must be master, the others must be
slaves. The master/slave selection is made with Dip-switch 2: OFF - Master (factory
setting), ON - Slave.
Go to "Doors" and click on the link "Add slave"(fig.1). Enter the serial number of the
WS4-4D-E to be added and click Search. If it finds it, the system directly adds this slave
into the installation and you can configure its doors (fig.2).
In case of error, a message is displayed in red.
Switch
fig.1
Master
Slave 1
Slave 9
DIP switch 2
DIP switch 2
DIP switch 2
OFF
ON
ON
Master/
Slave
fig.2
fig.2
fig.4
fig.6
fig.3
EN
1

Werbung

loading

Inhaltszusammenfassung für XPR Access WS4-4D-E

  • Seite 1 Yes, via Wiegand to RS485 converter - WS4-CNV fig.2 In this configuration, the WS4-4D-E will assign an IP address to your PC. The PC must be set to obtain IP • Elevator feature: Yes, 2 elevators per installation, each - 24 floors address automatically.
  • Seite 2 Connection example of 3 doors Emergency Box Tamper button Example of a door with 2 readers + electric strike fail close Network Door contact Example of a door with 1 reader + electric strike fail open electric strike (fail open) Push button electric strike (fail close) Reader...
  • Seite 3: Guide De Référence Rapide

    L’interrupteur DIP 4 permet de se connecter au système en tant qu’administrateur en cas d’oubli du nom d’utilisateur ou du mot Le WS4-4D-E ne comporte pas d’adresse IP par défaut. Il est réglé sur DHCP par défaut. La de passe. Placez cet interrupteur DIP sur MARCHE pendant connexion et la configuration du WS4 peuvent se faire selon deux méthodes différentes : LAN...
  • Seite 4 Exemple de connexion de trois portes Bouton Boîtier anti-sabotage d’urgence Exemple de porte avec deux lecteurs + gâche électrique avec fermeture en cas de panne Réseau Contact de porte Exemple de porte avec un lecteur + gâche électrique avec ouverture en cas de panne gâche électrique Bouton- (ouverture en cas de panne)
  • Seite 5 Sì, 2 ascensori per installazione, ciascuno - 24 piani fig.2 In questa configurazione, WS4-4D-E assegna un indirizzo IP al PC in uso. IL PC deve essere configurato per • Interblocco, Antiritorno, contapersone, presenza, registri di sistema, rapporti in CSV l’acquisizione automatica dell’indirizzo IP.
  • Seite 6 Esempio di connessione di 3 porte Pulsante di Manomissione scatola emergenza Esempio di una porta con 2 lettori + chiusura in caso di interruzione di corrente Rete Contatto porta Esempio di porta con 1 lettore +apertura in caso di interruzione di corrente lucchetto elettrico (apertura in caso di lucchetto elettrico...
  • Seite 7: Guía Rápida Del Usuario

    Vaya a “Puertas” y haga clic en el enlace “Agregar secundaria” (fig. 1). Introduzca el RESTABLECIMIENTO DE LOS VALORES DE FÁBRICA número de serie de la WS4-4D-E que se vaya a agregar y haga clic en Buscar. Si la encuen- El interruptor DIP 4 permite la reinicialización completa del tra, el sistema agrega directamente esta placa secundaria a la instalación y puede...
  • Seite 8 Ejemplo de conexión de 3 puertas Botón de Caja de control manual emergencia Ejemplo de una puerta con 2 lectores + fallo de cierre de la cerradura eléctrica Contacto de la puerta Ejemplo de una puerta con 1 lector + fallo de apertura de la cerradura eléctrica Cerradura eléctrica Botón (fallo de apertura)
  • Seite 9 • Verbindung mit Wiegandleser: Ja, über Wiegand-RS485-Konverter - WS4-CNV fig.2 Bei dieser Konfiguration weist der WS4-4D-E Ihrem PC eine IP-Adresse zu. Der PC muss so eingestellt sein, dass • Aufzugfunktion: Ja, 2 Aufzüge pro Installation, jeweils 24 Stockwerke er die IP-Adresse automatisch erhält.
  • Seite 10 Anwendungsbeispiel: Verbindung von drei Türen Notfallknopf Gehäusesabotage Tür mit zwei Lesern + elektrischem Türöffner (stromlos geschlossen) Netzwerk Türkontakt Tür mit einem Leser + elektrischem Türöffner (stromlos offen) Elektrischer Türöffner Drucktaster (stromlos offen) Elektrischer Türöffner (stromlos offen) AUSGANG EINGANG Leser Adresse 1 Adresse 0 12V/600mA max 12V/600mA max...
  • Seite 11: Beknopte Gebruikershandleiding

    • Aansluiting Wiegand lezers: Ja, via Wiegand op RS485-omzetter - WS4-CNV fig.2 In deze configuratie wijst WS4-4D-E een IP-adres toe aan uw pc. De pc moet worden ingesteld voor het • Liftfunctie: Ja, 2 liften per installatie, elk - 24 etages automatisch verkrijgen van een IP-adres.
  • Seite 12 Voorbeeld 3-deursverbinding Noodstop Behuizing sabotageschakelaar (tamper) -knop Voorbeeld van een deur met 2 lezers + elektrische deuropener sluiten mislukt Netwerk Deurcontact Voorbeeld van een deur met 1 lezer + elektrische deuropener openen mislukt elektrische deuropener (openen mislukt) Drukknop elektrische deuropener (sluiten mislukt) Lezer Adres 1...