Specific Operating Instructions
1
4
2
a.) Installation
Fastening holes (3) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall
with the connections at the bottom, see above picture, left part. For outside installation the device must also
be protected against exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device WITHOUT fence and connection to earth. The control lights flash in time to the impulses
(green or red). The device is ready for operation. If control lights do not flash, the power supply or power
supply line must be checked first. If no fault can be detected, the device should be tested by a specialist.
c.) Functional description with CONNECTED fence system (earthing + fence)
Control light
Flashing green:
1
"OK"
(1)
Flashing
Control light
2
red:
"CHECK" (2)
Connection variants:
Fence system closed:
The unit can be operated with a SEPARATE fence system connected to each fence connection (5 – 6).
If both fence exits are used simultaneously, the control light (1) refers to exit (6) with maximum energy.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
-
If the indicator light flashes faster than once per second, the appliance must be disconnected at once and
checked by a technician before it can be used again.
Ensure a good grounding of the devices, with at least 3 ground rods, Item No.: 44219.
5
Mains plug is used as ON / OFF!
Connection to 230 V ~!
State of fence/ earth ok = output voltage > 4000V = OK
CHECK = State of fence faulty = output voltage ≤ 4000V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5)
CHECK = State of connection to earth faulty, see operating instructions enclosed,
possible sources of error (fig. 2, pg.5) and connection to earth (pg.4)
earth
Erdung
3
This energizer shall not be used 
as an animal trainer  
(inside a barn). 
6
Fence system open:
3
DELTA 5
1
Indicator light "OK"
2
Indicator light "CHECK"
3
Fastening holes
4
Earth connection
Fence connection
5
with reduced energy
Fence connection
with maximum energy
6
earth
-EN-
Version : 2019.1