Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Guide - Renfert 933-0100 Original Bedienungsanleitung

Sicherheitsbrenner
Vorschau ausblenden Andere Handbücher für 933-0100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4
Handling
You can choose the size of the safety burner's flame using the tipping lever.
EN
Position A:
Position B:
Position C:
When choosing either position A or C always turn the tipping lever to its limit. By doing this you can
identify quickly and unmistakably which position the burner was in should the flame ever go out. This will
also prevent a flash-back in the burner's nozzle.
Regulating the main flame:
• Where?
• How?
Regulating the pilot flame:
• Where?
• How?
The ignition flame should be as stable, and therefore as smooth, as possible in order to ensure a reliable
burner operation. Adjust the flame so that it cannot be extinguished unintentionally.
Adjusting the burner position:
The burner can be positioned at three different angles:
To adjust the burner to the angle which suits you the best, simply lift it out of its base and reinsert it in the
required position. The burner is thus equally well suited for left-handed and right-handed users.
The burner should not be used in the 90° position when working with wax, since dripping wax may block
the jets and cause the burner to malfunction.
5

Troubleshooting Guide

Fault
Burner will not ignite despi-
te open shut-off valve, no
audible flow.
Burner will not ignite despi-
te clearly audible gasflow.
Smell of gas when burner
is ignited.
Ignition or pilot flame burns
Main flame and ignition flame burn
Main flame burns
The knurled nut on the large burner pipe.
Gentle flame: turn the knurled nut upwards (reducing air supply).
Harsh flame: turn the knurled nut downwards (increasing air supply).
The sleeve over the air supply holes on the small burner pipe.
Gentle flame: slide the sleeve over the air supply holes.
Harsh flame: slide the sleeve away from the air supply holes (unstable flame).
Cause
• The main gas supply has not been switched
on / gas bottle is empty.
• Gas lever not pressed.
• Nozzle is blocked.
• Incompatible connecting values.
• Caution:
faulty pressure reducer.
• Faulty thermoelement.
• Leaky connections.
• Leaky burner.
Remedy
• Operational error.
• Operational error.
• Screw off burner tubes and carefully clean the
jets with a soft cloth.
Do not screw out the jets!
• Check connection pressure and gas type.
• Replace pressure reducer.
• Send the burner in for repair.
• Examine connections.
• Do not repair yourself. Send the burner to be
examined.
- 2 -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

932-0100

Inhaltsverzeichnis