Herunterladen Diese Seite drucken

axing basic-line BVS 10-00 Betriebsanleitung Seite 3

Vorschau ausblenden Andere Handbücher für basic-line BVS 10-00:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety advices:
 Installation and repairs to the equipment may only be carried out by
technicians observing the current guidelines. No liability will be assumed
in the case of faulty installation and commissioning.
 Choose the location of installation or mounting so that the power plug
can be reached and pulled out of the socket easily in case of danger.
 Choose the location of installation or mounting such that children may
not play unsupervised near the equipment and its connections. The
location of installation or mounting must allow a safe installation of all
cables connected. Power feeding cables as well as feeder lines may not
be damaged or clamped by objects of any kind. To prevent damage to
your equipment and to avoid possible peripheral damages, the devices
foreseen for wall mounting may only be installed on a flat surface.
 Choose the location of installation or mounting so that under no
circumstances liquids or objects can get into the equipment (e.g.
condensation, water coming from leaking roofs or flowing water, etc.).
 Avoid exposure of the equipment to direct sunlight and to other heat
sources (e. g. radiators. other electrical devices, chimney, etc.). Devices
that are equipped with heat sinks or ventilation slots must under no
circum-stances be covered or blocked. Also ensure for a generous
air circulation around the equipment. In this way you avoid possible
damage to the equipment as well as a risk of fire caused by overheating.
Absolutely avoid that cables come near any source of heat (e.g.
radioators, other electrical devices, chimney, etc.).
State of the art 2019-12-16
Technical improvements, changes in design, printing- and other errors expected.
Technical data
Type
BVS 10-00
EMC
according to EN 50083-2, class A
Downstream
Frequency range
Gain
18...20 dB
Max. output level
(3rd order, EN 50083-3, 60 dB KMA)
Max. output level
(2nd order, EN 50083-3, 60 dB IMA)
Attenuation: continuously adjustable
-
Return loss
≥ 14 dB (-1,5 dB/Octave)
Noise figure typ.
RF connectors
Type
General
Remote voltage
12 V=
Current consumption
≤ 65 mA
Max. through-current
1000 mA
Operating temperature range
(acc. to EN 60065)
Dimensions (W × H × D) appr.
Herewith AXING AG declares that the marked products comply with the valid
guidelines.
WEEE Nr. DE26869279 | Electrical and electronic components must not be
disposed of as residual waste, it must be disposed of separately.
Manufacturer
EEA contact address
AXING AG
Bechler GmbH
Gewerbehaus Moskau
Am Rebberg 44
8262 Ramsen
78239 Rielasingen
BVS 10-30
BVS 10-02
47...862 MHz
27...30 dB
10 dB
102 dBµV
92 dBµV
BVS 10-00
0...18 dB
-
BVS 10-02
≤ 8 dB
F-female
BVS 10-30
12 V=
5/6 V=
≤ 100 mA
≤ 30 mA
basic-line
300 mA
1000 mA
-20...+50°C
Inline amplifiers
85 × 26 × 20 mm
Operation instructions

Werbung

loading

Diese Anleitung auch für:

Basic-line bvs 10-02Basic-line bvs 10-30