5. FIRST STARTING OF MACHINE
Before starting the dehumidifier, make sure that the machine has been standing in vertical position for at-least 8 hours. If one fails
to observe this procedure, irreparable damage may be caused to the compressor. Then one can proceed and connect the
dehumidifier plug to a 230 V - one phase power socket.
The red light 'POWER' will switch on confirming correct supply of power to the machine. If the light 'WORKING' is still off, turn
clockwise the knob on the control panel till the light 'WORKING' is ON. The light 'DEFROST (PAUSE) will also switch on and, after
about 5 minutes the dehumidifier will start dehumidifying.
When the red light is "ON" (ALARM), the machine wiil not start: one must check that the water tank be empty and, then, that be set
in correctly; with the machines provided with pump, check that the pump function be working and that the delivry pump may be
clear.
AND IF THE DEHUMIDIFIER DOES NOT START OR DEHUMIDIFY ?
First make sure that the red light 'POWER' is 'ON': this means that the current is fed to the machine. If the power supply light is not
on, make sure that the connecting wire plug may be properly inserted into a main line socket in the room. After checking all this, if
the power light is still off, then call the dealers service.
Make sure that the green light 'FULL' be off; If this is not the case, check the correct position of the draining pipe (see point 4.)
Make sure that the red light 'RUNNING' be 'on'; this means that the Humidostat activates the functioning of the machine. When the
dehumidifier is set again to functioning, after an idle period due to the reaching of the preset humidity or after emptying the water
tank, if the Humidostat requires functioning of the machine, then beside the two red central lights, also the red light 'Pause' will light
up. During this 5 minutes long phase, only the motor fan is running whereas the compressor is off. This operating cycle take place
every 45 minutes to allow the defrosting of the cooler. When the red light 'Pause' will remain off for a period longer than 6 minutes,
the dehumidifier should be brought to Dealer's service centre.
When the machine appears to be working correctly ( the two central red lights are on), but it is not producing condensed water or
produces only very little condensed water, it should be checked whether the relative humidity in the room may be lower than
40.45%; if the relative humidity is higher than that, the machine should be controlled by the dealer's service.

6. PERIODICAL MAINTENANCE

AIR FILTER CLEANING
The only required periodical maintenance is the cleaning of the filter once every month, or more often if the enviroment is very
dusty or the dehumidifier is working for many hours every day.
The cleaning must be done by placing the filter under a water jet with the drilled panel facing the floor so that the water jet may
push the filter towards the drilled panel.
After a few years running, may be necessari to make a cleaning of the warm heat exchanger (condenser) by using compressed air.
This operation must be done by a specialized technician. This cleaning will improve the performaces and the long life of the
machine.
Note: You can require spare filters from your dealer's service.